General Information continued-
This water heater has been manufactured for operation at altitudes from sea
level to 2000 feet (610m) (unless otherwise specified on the water heater).
For use of this appliance at an elevation greater than 2000 feet (610m), contact
the dealer or manufacturer listed on the rating plate for information on any
necessary modification. Uncorrected operation of this appliance may create a
hazard to life and property.
Make sure to check the rating plate and combination gas control on the water
heater to be certain that the type of gas being supplied corresponds with the
marking on the rating plate and combination gas control.
A sacrificial anode is used to extend tank life. The removal of this anode, for
any reason, will nullify the warranty. In areas where water is unusually active,
an odor may occur at the hot water faucet due to a reaction between the
sacrificial anode and the impurities in the water. If this should happen, an
alternative anode may be purchased from the supplier that installed this water
heater. This will minimize the odor while protecting the tank. Additionally, the
water heater should be flushed with appropriate dissolvers to eliminate any
bacteria.
INSTALLATION
Locating the Water Heater
This water heater MUST NOT be installed in any location where gasoline or
flammable vapors are likely to be present, unless the installation is such to
eliminate the probable ignition of gasoline or flammable vapors.
The location of this water heater is of the utmost importance. Before installing
this water heater, read the Installation section of these instructions. DO NOT
locate the water heater where water lines could be subjected to freezing
temperatures. Make sure the cold water pipes are not located directly
above the gas control so that condensate during humid weather does not
drip on the controls.
Do not store or use gasoline or other flammable, combustible, or
corrosive vapors and liquids in the vicinity of this or any other
appliance.
DANGER
WARNING
Water heaters are heat producing appliances. To avoid damage or injury there must
be no materials stored against the water heater or vent-air intake system and proper
care must be taken to avoid unnecessary contact (especially by children) with the
water heater and vent-air intake components. UNDER NO CIRCUMSTANCES MAY
FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE
USED OR STORED IN THE VICINITY OF THIS WATER HEATER, VENT-AIR
INTAKE SYSTEM OR IN ANY LOCATION FROM WHICH FUMES COULD
REACH THE WATER HEATER OR VENT-AIR INTAKE SYSTEM.