Bosch Appliances IVMD 1.0 Home Security System User Manual


 
16 en | Area settings IVMD | Configuration instructions
1.0 | 2006.04 BOSCH Security Systems
4.2.1 Detector field
Detector fields are displayed as framed areas with a grid pat-
tern. The particular status of a detector field is indicated by the
different colors:
When you click a detector field, its 'nodes' (corners) are high-
lighted by circles and you can edit the detector field.
Nodes can be inserted or deleted. The sides and nodes of a
detector field can be repositioned as desired. However, the
sides of a detector field must not cross over, and distorted
fields are not accepted.
Detector fields can be copied and inserted.
Green field Detector field in which no object that gener-
ates an alarm event was detected.
Light green Detector field is clicked and activated for edit-
ing.
Green Mouse cursor is over the detector field; right
click to see the context menu for the detector
field.
Dark green Mouse cursor is not over this detector field;
right click to see the general context menu for
setting an area (or the context menu of another
detector field).
Red field Detector field in which an object that gener-
ates an alarm event was detected.
Light red Detector field is clicked and activated for edit-
ing.
Red Mouse cursor is over the detector field; right
click to see the context menu for the detector
field.
Dark red Mouse cursor is not over this detector field;
right click to see the general context menu for
setting an area (or the context menu of another
detector field).