30 en | Area settings IVMD | Configuration instructions
1.0 | 2006.04 BOSCH Security Systems
Trigger
Mode: An alarm event is generated when...
Entering ...the center of the object moves across the
boundary of the detector field and into the
field.
Debounce time: If a value other than 0
(zero) is selected, the alarm event will not
be generated until the center of the object
has fully crossed the boundary of the
detector field after this time. This prevents
objects triggering a large number of alarm
events when they are moving around on
the edge of the detector field.
Leaving ...the center of the object moves across the
boundary of the detector field and out of
the field.
Debounce time: as for entering objects,
see above.
Inside ...the center of the object moves inside the
detector field.
Delay [s]: If a value other than 0 (zero) is
selected, the alarm event will not be gener-
ated until the object has moved or been
inside the detector field for at least the
selected delay time.
i
NOTE!
If the boundary of the detector field lies across a static object
that can conceal a moving object (e.g. advertising hoarding),
entering or leaving may not be detected.