26 en | Subsystem Monitoring RAID Subsystem DVA-16K | Installation Manual
F.01U.027.799 | V2 | 2008.08 Bosch Security System
Three (3) LEDs monitor the status of the system. The definitions of these LEDs are given
below.
Fig. 4.1 LCD Panel
Name Color Status
PWR
(Power)
Blue ON indicates that power is being supplied to the
subsystem.
OFF indicates that no power is being supplied to the
subsystem.
BUSY White FLASHING indicates that there is activity on the
host/drive channels.
OFF indicates that there is no actively on the host/
drive channels.
ATTEN
(Attention)
Red ON indicates that a component failure/status event
has occurred.
OFF indicates that the subsystem and all its compo-
nents are operating correctly.
Table 4.2 LCD Panel LED Definitions
i
NOTICE!
During the power up process, the LCD panel ATTEN LED will be turned on. If the subsystem
boots up correctly, then the ATTEN LED will be turned off after the boot-up procedure is com-
plete.