Bosch Appliances DS7400XIV4-EXP Home Security System User Manual


 
DS7400XiV4-EXP | User Guide | 4.0 Understanding the Text and LED Keypads EN | 5
Bosch Security Systems | 6/05 | 4998154961B
4.0 Understanding the Text and
LED Keypads
DS7447E/DS7447V2 are alpha-numeric LCD keypads.
DS7445i/DS7445V2 are LED keypads; its LEDs (1 to
16) represent the first 16 zones of the system. Both
display information about control panel functions. A
built-in sounder is used to annunciate keystroke entries
and functions as an interior warning device.
The front of your keypad might look different than the
keypads shown below. The instructions in this
document still apply as the functions are the same.
(For other keypad operations, refer to Section 11.0 The
Master Keypad on page 31.)
Figure 1: Text and LED Keypads
1 23
456
789
0
*
#
12345678
910
11
1213
14
15
16
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenced
Troubl e
System
Reset
Bypass
No
Entry
Perimeter
Only
Off
On
Armed
Status
Power
Fire
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
TEST WEEKLY
LED Keypad Text Keypad
Table 1: Keypad LEDs
LED Off Flashing On
Armed
(red)
All areas are disarmed. One or more areas are armed, or
an alarm occurred.
All partitions are armed, and no alarms
occurred.
Status
(green)
Not ready to arm (if the Armed LED
is on, all areas are armed).
One or more zones are
bypassed.
All areas are ready to arm.
Power
(green)
The control panel has lost all
power; no AC or battery.
Control panel problems exist.
Refer to Section 9.0 Error
Displays.
Normal Operation. The control panel is
running on AC power with no problems.
Fire
(red)
There are no fire alarms. A fire zone is in alarm. A fire trouble condition exists.
These status LEDs are present only on the LED Keypad:
Table 2: Status LEDs
LED Off Flashing On
Perimeter
(yellow)
Control panel is disarmed or is not
perimeter armed.
This LED does not flash. The perimeter is armed.
Supervisory
(yellow)
There are no supervisory alarms
present.
A supervisory condition exists. This LED does not turn on steady.
Bell
Silenced
(red)
The bells do not have to be or are
not silenced.
This LED does not flash. There was a fire alarm and the bells
were silenced. To clear, enter the Fire
Reset command: [PIN][System Reset]
Trouble
(yellow)
There are no trouble conditions. This LED does not flash. A trouble condition exists.
LEDs 1 to
16 (red)
There are no zone alarms. A zone (1 to 16) is alarmed. A zone (1 to 16) is not ready to arm,
or if a fire zone, a trouble exists.
Volume Control
You can adjust the keypad sounder volume using the
[1] and [4] keys with the [*] key.
Hold the [*] key and press the [1] key to increase the
volume or the [4] key to decrease the volume.
Backlight Control (Text Keypad Only)
You can adjust the display backlight intensity using the
[3] and [6] keys with the [*] key.
Hold the [*] key and press the [3] key to increase the
brightness or the [6] key to decrease the brightness.
After adjusting the backlight and volume,
you must arm and disarm the system once
to store this information in the control panel.
If power is disconnected before the control
panel is armed, the backlight and volume
levels return to the default settings.