Bosch Appliances 8008 Home Security System User Manual


 
Installation and Operating Manual | VideoJet 8008 / VideoJet 8004
EN | 52
Configuration using a Web browser Bosch Security Systems | 2006-07 | V1.5
Name:
You can enter a name for each alarm input, which is then displayed below the
icon for the alarm input on the LIVEPAGE if configured correctly
(see Livepage configuration, page 112).
Video loss alarm:
Activate the checkbox if you want an interruption of the video signal to trigger an
alarm. A selected video input is indicated by a check mark.
Note
The numbering is the same as the labeling of the video inputs on the rear
panel of the unit.
1. SNMP host address / 2. SNMP host address:
The unit supports the SNMP (Simple Network Management Protocol) for man-
aging and monitoring network components and can send SNMP messages to
IP addresses. It supports SNMP MIB II and its traps in their full functionality in
the unified code. If you wish to send SNMP traps, enter the IP addresses of one
or two required target devices here. UDP Port 161 is generally used as the port
for the SNMP functionalities.