Bosch Appliances 28i junior Boiler User Manual


 
FLUE OPTIONS
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior
8 716 107 336b (11/05)
17
PRE -
INSTALLATION
FLUE OPTIONS
The diagrams (opposite) show the
components used and the maximum flue
length for each configuration of 100mm and
125mm flues.
Shaded flue components indicate the
standard 100mm horizontal flue.
Only straight flue sections can be reduced in
length and cut.
The flue terminal end can be fitted from the
inside or outside of the building.
Fixing kits are supplied with the flue extension
kits.
Horizontal 125mm and Vertical 100mm and
125mm flue kits are available with separate
instructions. Contact your supplier or
Worcester.
A - Standard horizontal flue (100mm diameter
shown)
B - Straight flue extension
C - Flue bend 90°
D - Flue bend 45°
E - Vertical terminal (vertical adaptor supplied
with terminal)
F - Vertical adaptor (used with horizontal
terminal)
Calculating the flue length:
Measure the total flue length required, noting
that the max
imum straight flue length including
the terminal is:
Horizontal 60/100mm: 4600mm
Horizontal 80/125mm: 13000mm
Vertical 60/100mm: 6400mm
Vertical 80/125mm: 15000mm
Then reduce the total straight flue length for
each extra flue bend (excluding the flue elbow)
by:
2000mm for 90°
1000mm for 45°
Flue Extension lengths:
Horizontal & Vertical 60/100mm: 960mm
Horizontal & Vertical 80/125mm: 1000mm
Flue Terminal lengths:
Horizontal 60/100mm: 800mm including terminal
Horizontal 80/125mm: 1200mm including terminal
Vertical 60/100mm: 1140mm to top of terminal
Vertical 80/125mm: 1365mm to top of terminal
STANDARD FLUE HORIZONTAL
Ø100
MAX 686 A x 1
MIN 250 A x 1*
Ø125
MAX 1070 A x 1
MIN 250 A x 1*
* Requires cutting
MAXIMUM FLUE HORIZONTAL
Ø100 - 4600mm
A x 1 + B x 5
Ø125 - 13000mm
A x 1 + B x 13
MAXIMUM FLUE VERTICAL START + 1 BEND
Ø100 - 4600mm
A x 1 + C x 1 + B x 5 +
Fx1
Ø125 - 13000mm
A x 1 + C x 1 + B x 13 +
Fx1
Ø100 - 2600mm
A x 1 + B x 3 + C x 1
Ø125 - 11000mm
A x 1 + B x 11 + C x 1
MAXIMUM FLUE HORIZONTAL + 1 BEND
MAXIMUM FLUE VERTICAL
START + 2 BENDS
Ø100 - 2600mm
A x 1 + C x 2 + B x 4 +
Fx1
Ø125 - 11000mm
A x 1 + C x 2 + B x 13 +
Fx1
Ø100 - N/A
Ø125 - 9000mm
A x 1 + C x 3 + B x 11 +
Fx1
MAXIMUM FLUE VERTICAL
WITH 2 x 45° BENDS
Ø100 - 4400mm
(including terminal)
B x 5 + D x 2 + E x 1
Ø125 - 13000mm
(including terminal)
B x 13 + D X 2 + E x 1
Ø100 - 2400mm
(including terminal)
B x 4 + C x 2 + E x 1
Ø125 - 11000mm
(including terminal)
B x 13 + C x 2 + E x 1
VERTICAL FLUE WITH
2 x 90° BENDS
A
A
B
A
B
F
C
A
B
C
F
B
C
A
F
B
C
A
E
B
D
E
B
C
MAXIMUM FLUE VERTICAL
START + 3 BENDS