Black & Decker MULTI-GAS DETECTORS Carbon Monoxide Alarm User Manual


 
GAS DETECTION
CALL FAX CALL US TODAY
800.833.0247 800.282.4365 www.safetyfire.com
281.479.9700 281.479.6321 –379–
BIOSYSTEMS PhD
5
ACCESSORIES
Standard Accessories:
Each PhD5 detector is shipped complete with leather case, carrying strap, hand aspirated sample draw kit with 10
feet of tubing, operator’s guide, reference manual, quick reference card, and comprehensive training video. The
sample draw kit includes sample draw/calibration adapter, squeeze bulb, tubing, sample probe, and spare sample
probe filters. “Alkaline” PhD5 detectors include and alkaline battery pack and set of three AA disposable batteries.
“Ni-Cad” PhD5 detectors include a Ni-Cad battery pack and slip-in “Datadock”/Fast Charger as well as a spare alka-
line battery pack and set of three AA disposable batteries.
PhD
5
Remote Accessories:
Part No. Description
54-27-0101 Continuous sample pump for PhD
5
, slip on. Includes 10' of tubing and sample probe assembly.‡
54-27-0102 Continuous sample pump for PhD
5
, screw on. Includes 10' tubing and sample probe assembly.
54-05-A0401 Sample draw kit for PhD
5
. Includes adapter, squeeze bulb, 10' of tubing and sample probe
assembly. Not for use with CI
2, CIO2
54-05-A0403 Sample probe assembly. Does not include tubing, squeeze bulb, or sample draw adapter.
54-05-A0405 Sample probe assembly with 11.5 inch stainless steel probe tube. Does not include tubing,
squeeze bulb, or sample draw adapter
10-263 Sample draw/calibration adapter for PhD
5
.
PhD
5
“Smart Sensors”
Part No. Description Range
54-25-80 LEL Combustible Gas 0-100%LEL
54-25-90 O2 Oxygen 0-30%/Vol.
54-25-01 CO Carbon Monoxide 0-1000 PPM
54-25-02 H2S Hydrogen Sulfide 0-200 PPM
54-25-14 Duo-Tox Dual Channel CO / H2S CO: 0-1000 PPM
Provides substance specific readouts for CO & H2S H2S: 0-200 PPM
54-25-03 SO2 Sulphur Dioxide 0-25 PPM
54-25-21* HN3 Ammonia 0-300 PPM
54-25-08* ** CL2 Chlorine (non-specific) 0-50 PPM
54-25-18* ** CL2 Chlorine (specific) 0-50 PPM
54-25-12* ** CIO2 Chlorine Dioxide (non-specific) 0-15 PPM
54-25-20* ** CIO3 Chlorine Dioxide (specific) 0-5 PPM
* Special corrosive gas calibration adapter (No. 54-26-0405) required for proper calibration.
** The non-specific CL2 and CIO2 sensors can be used for the detection of both gases.
The specific CL2 and CIO2 sensors are designed for the target gas only.
PhD
5
Calibration Kit
Part No. Description
54-27-0501 Calibration Kit for PhD5 includes foam lined carrying case with room for up to three cylinders of
calibration gas. Kit contains 12-023 regulator and other fittings. Kit does not include gas.