16
Routine Maintenance Continued
Remove and rinse tools in clean, running water. Dry and
replace on Tool Caddy.
Coil Flex Hose around storage brackets on Tool Caddy.
Remove Tank-In-Tank, dispose of dirty water. Refer to the
Features section on Pages 8-9.
Rinse out Tank-In-Tank and replace on the machine; Clean out
Lint Screen.
Clean out the Flow Indicator Filter each time it is used to ensure
best cleaning performance. Unscrew the Flow Indicator Cap, lift
out the Red Rotor and White Filter. Rinse all three parts in tap
water. Replace the Filter and Rotor. Replace the Flow Indicator
Cap; turn until snug, do not over-tighten.
Wipe all exterior surface with a soft cloth.
Store cleaner upright in a protected, dry area.
Note: PowerWash ProHeat uses water and must not be
stored where there is a danger of freezing. Freezing will
damage internal components and void the warranty.
When carpet is dry, vacuum again to remove hair and fuzz
that the PowerWash ProHeat may have loosened.
Turn the Power Switch OFF and unplug from the outlet.
Step on the Handle Release and recline the handle down onto
floor (see illustration).
Remove Tank-In-Tank and SmartMix Bottle. Set them aside
(see illustration).
Remove Belt Access Door located near the Floor Cleaning/
Tools switch by inserting a flat head screwdriver into the slot
nearest to the handle and gently prying the access door off
(see illustration).
Turn the machine onto its side so the belt access area is
facing upward (see illustration).
On the bottom of the machine, near the belt access area,
is a red retainer plate that holds the black brush arm and
brush in place. Using a Phillips head screwdriver remove the
screw that holds the red retainer plate in place. Set red
retainer plate and Phillips head screw aside (see illustration).
4.
5.
6.
7.
8.
9.
10.
Cap
Rotor
Filter
3.
Pump Belt Replacement
1.
2.
3.
4.
5.
6.
2
3b
5
6
3a
4
O
N
O
F
F