Beckett CF 2300A Burner User Manual


 
Instruction Manual – Model CF2300A Oil Burner
7
Form 6104 BCF-23-R0399
Figure 5 – Nozzle line assembly in burner
Set dimension Z
Replace the rear access door on the
burner, making sure that the adjust-
ing plate assembly is now securely
held in place.
Loosen acorn nut d in Figure 5.
Slide the nozzle line and plate as-
sembly until dimension Z in
Figure 5 is
1³⁄₄1³⁄₄
1³⁄₄1³⁄₄
1³⁄₄" ±
¹⁄₁₆¹⁄₁₆
¹⁄₁₆¹⁄₁₆
¹⁄₁₆". When di-
mension Z (from end of air tube to
flat area of front face of head) is cor-
rectly set, tighten acorn nut d. Verify
Figure 6 – Adjusting plate assy.
Legend (Figures 5 and 6)
a Adjusting plate assembly
b Spline nut for securing nozzle line
c Bottom acorn nut
d Top acorn nut (for setting dim. Z
only)
e Indicator adjusting plate
f Secondary adjusting plate
g Primary adjusting plate
that the adjusting plate assembly is
properly seated at the rear access
door, as shown in Figure 5.
Attach the oil line from the oil valve
to the nozzle line end. Tighten se-
curely.
Before proceeding, check dimen-
sion Z once again. Loosen acorn nut
d if necessary to reposition the
nozzle line. Once dimension Z is set,
do not loosen acorn nut d again.
For the setting of acorn nut c, refer
to page 12.
Insert burner
Position the burner in the front of
the appliance and loosely tighten
the nuts on the mounting studs. The
burner should be pitched downward
2° as shown in Figures 3 and 7.
See Figure 7. Install the pedestal
support kit (recommended) by at-
taching the ¾" npt flange (item a)
to the bottom of the burner using
the (4) #10 screws provided. Cut and
thread (one end only) a ¾" pipe
nipple (item b) with length 11
inches less than dimension D in Fig-
ure 7
. Thread the pipe into the
flange. Then slip the pipe end into
the floor flange (item c).
Secure the burner to the appliance
by tightening the nuts on the burner
flange mounting studs. Then secure
the pedestal support floor flange set
screw to the pipe.
Figure 7 – Burner installed in appliance front
Legend
H Housing total length — 18½"
J Center to bottom of housing — 10½"
Z
2308
a
Measure dimension from
front (flat) face of head to
end of air tube, as shown.
Z
b
c
d
Measure dimension Z from the flat
surface between (not on) the raised fins.
2324
2303
D
H
K
J
a
b
c
1¾"
2308-1
e f
g
cd
K Overall housing height — 15
⁵⁄₈⁵⁄₈
⁵⁄₈⁵⁄₈
⁵⁄₈"