Beckett CF2500A Burner User Manual


 
Smith Cast Iron Boilers
18
Series Boiler
Boiler
Burner
Chassis
Spec.
Air Tube
Combination
High
Fire
Rate
Nozzle
Head
Setting
Blue -
Low Fire
Air or
Shutter
Red -
High Fire
Air or
Band
Low Fire
Pump
Press.
High Fire
Pump
Press.
Pressure
Firing
Flange
Insertion
18-4 CF500 BCF809 CF60KK 2.55 2.25x60PLP 1-1/2 4 0 N/A 140 51628 3.875"
18-5 CF500 BCF809 CF60KK 3.25 2.75x60PLP 3 5 0 N/A 140 51628 3.875"
18-6 CF500 BCF809 CF60KK 4.00 3.50x60PLP 5 10 4 N/A 140 51628 3.875"
18-7 CF500 BCF809 CF60KK 4.70 4.00x60PLP 6 10 10 N/A 140 51628 3.875"
18-7 CF800 BCF403 CF60KJ 4.70 4.00x60PLP 1 7 0 N/A 140 51628 3.875"
18-8 CF800 BCF403 CF60KJ 5.40 4.50x60PLP 2 10 0 N/A 140 51628 3.875"
18-9 CF800 BCF403 CF60KJ 6.10 5.00x60PLP 4 10 3 N/A 140 51628 3.875"
18-10 CF800 BCF403 CF60KJ 6.90 6.00x60PLP 5 10 8 N/A 140 51628 3.875"
18-10 CF1400 BCF205 CF66KD 6.90 4.00x45PLP 3 25 60 125 300 51629 3.875"
18-11 CF1000 BCF101 CF66KE 7.60 4.50x45PLP 4 20 N/A N/A 300 51629 3.875"
18-11 CF1400 BCF205 CF66KD 7.60 4.50x45PLP 4 30 60 125 300 51629 3.875"
18-12 CF1000 BCF101 CF66KE 8.30 5.00x45PLP 4-1/2 21 N/A N/A 300 51629 3.875"
18-12 CF1400 BCF205 CF66KD 8.30 5.00x45PLP 5 25 70 125 300 51629 3.875"
Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Page 25