Beckett CF2500A Burner User Manual


 
Peerless Boiler
EC/ECT
Series Boiler
Boiler
Burner
Chassis
Spec.
Air Tube
Combination
High
Fire
Rate
Nozzle
Head
Setting
Blue -
Low Fire
Air or
Shutter
Red -
High Fire
Air or
Band
Low Fire
Pump
Press.
High Fire
Pump
Press.
Pressure
Firing
Flange
Insertion
EC-06 CF375 BCF3907 CF56KZ 2.75 2.25x45P 1 10 6 N/A 140 51311 2.50"
EC-06 CF375 BCF3907 CF56KZ 3.00 2.50x45P 3 10 7 N/A 140 51311 2.50"
Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Peerless Boiler
JO-FDA
Series Boiler
Boiler
Burner
Chassis
Spec.
Air Tube
Combination
High
Fire
Rate
Nozzle
Head
Setting
Blue -
Low Fire
Air or
Shutter
Red -
High Fire
Air or
Band
Low Fire
Pump
Press.
High Fire
Pump
Press.
Pressure
Firing
Flange
Insertion
JO-6FDA CF800 BCF403 CF60KH 3.50 3.00x45B 0 5 0 N/A 140 51311 2.50"
JO-7FDA CF800 BCF403 CF60KH 4.00 3.50x60B 1 8 0 N/A 140 51311 2.50"
JO-8FDA CF800 BCF403 CF60KH 4.50 4.00x60B 2 10 0 N/A 140 51311 2.50"
JO-9FDA CF800 BCF403 CF60KH 5.00 4.50x60B 4 10 2 N/A 140 51311 2.50"
JO-10FDA CF800 BCF403 CF60KH 6.00 5.00x60B 5 10 6 N/A 140 51311 2.50"
Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.