Beckett CF2300A Burner User Manual


 
Easco Boiler
ESP
Series Boiler
Boiler
Burner
Chassis
Spec.
Air Tube
Combination
High
Fire
Rate
Nozzle
Head
Setting
Blue -
Low Fire
Air or
Shutter
Red -
High Fire
Air or
Band
Low Fire
Pump
Press.
High Fire
Pump
Press.
Pressure
Firing
Flange
Insertion
70 CF2500 BCF1801 CF102KP 21.00 6.00x45P (2) 5 10 50 300 300 51630 5.00"
80 CF3500 BCF1301 CF80KM 24.00 6.50x45P (2) 2 20 80 300 300 51630 5.00"
90 CF3500 BCF1301 CF114KR 27.00 7.50x45P (2) 6 25 85 300 300 51631 5.00"
100 CF3500 BCF1301 CF114KR 30.00 8.50x45P (2) 7 35 95 300 300 51631 5.00"
Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Flange requires an additional adapter plate.
Easco Boiler
FST
Series Boiler
Boiler
Burner
Chassis
Spec.
Air Tube
Combination
High
Fire
Rate
Nozzle
Head
Setting
Blue -
Low Fire
Air or
Shutter
Red -
High Fire
Air or
Band
Low Fire
Pump
Press.
High Fire
Pump
Press.
Pressure
Firing
Flange
Insertion
20 CF800 BCF403 CF100KH 6.00 4.50x45P 3 10 3 N/A 150 51628 5.00"
20 CF1400 BCF205 CF102KE 6.10 3.50x45P 1/2 20 40 150 300 51629 5.00"
32 CF1400 BCF205 CF102KE 9.60 5.50x45P 4 35 70 150 300 51629 5.00"
40 CF2300A BCF304 CF102KG 12.00 6.50x45P 1 17 30 150 300 51630 5.00"
50 CF2300A BCF304 CF102KG 15.60 8.50x45P 4 35 75 150 300 51630 5.00"
60 CF2300A BCF304 CF102KG 18.00 10.00x45P 5 30 60 150 300 51630 5.00"
70 CF2500 BCF1801 CF102KP 21.00 6.00x45P (2) 5 20 50 300 300 51630 5.00"
80 CF3500 BCF1301 CF80KM 24.00 6.50x45P (2) 2 20 80 300 300 51630 5.00"
90 CF3500 BCF1301 CF114KR 27.00 7.50x45P (2) 6 25 85 300 300 51631 5.00"
100 CF3500 BCF1301 CF114KR 30.00 8.50x45P (2) 7 35 95 300 300 51631 5.00"
Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Flange requires an additional adapter plate.
Page 15