Aquacal 111 Heat Pump User Manual


 
11
NOTE: THE HEATER CONTROLLER INCORPORATES AN ANTI-SHORT CYCLE TIME DELAY. SHOULD OPERATION BE
INTERRUPTED
, COMPRESSOR RESTART WILL BE DELAYED BY APPROXIMATELY 4-MINUTES.
HEATING-QUICK START & STOP (continued):
(End...Quick-Start & Stop)
6. To Stop the Heat Pump:
A. Select: OFF via the MODE selector. This method of shut down preserves the controller
settings;
B. An interruption of water flow–such as when a pump timer is in control–will also halt heat
pump operation.
5. Continuous Usage and Water Around Heater:
Condensation... After the heat pump has been operating for some time, water may be observed
surrounding the heater. The moisture seen is condensation produced as a normal by-product of
transferring heat from the air into the pool or spa water. Quantities of 6-8 gallons of water produced
per hour are common if the air humidity is high. Conversely, a low humidity condition may result in
no condensation being produced. (If water around unit seems excessive, to troubleshoot, see
page-26, “Water Coming from the Heat Pump.”)
4. Program Filter Pump Run Time:
Most pool/spa systems utilize a timer or multifunction controller to manage filter pump run times.
If your system incorporates such a device, follow the instructions below:
A. It will be necessary to allow the filter pump to run continuously until the water has reached the
desired temperature. If a timer controls the pool filter pump, it will be necessary to override
the timer to allow 24-hr. operation.
B. Once the desired temperature has been obtained (1-4 days), reset the pump control device.
Colder months require longer running times–generally eight to twelve hours/day.
C. A heat pump can only operate when the filter pump is running. Therefore, it may be
necessary–during cooler weather–to extend the water pump’s hours of daily operation.
The increased run time is necessary in order to keep up with increased, weather-related
heat losses.
3. To Begin Heating:
A. Verify MODE is set to: HEAT (HEA); then, depending on which body of water is to be heated,
use the POOL / SPA selector key to select POOL or SPA.
B. Position water valves to flow water from the pool or spa, through the heater, and back to the
pool or spa.
C. Start the water pump; the fan will start, and after 4-minute time delay the unit will begin
heating. The selected body of water will be brought to temperature and maintained per the
setting determined previously in: “Set the Heater Controls.”
D. In operation, whenever the actual (displayed) water temperature falls below the desired set
point, after an initial time delay of 4-minutes, the unit will begin heating.