Instruction manual BFC 17
is
3 Installation
Warning
Installation work should be carried out by an approved installation engineer
in compliance with the general and local regulations imposed by the gas, water
and power supply companies and the fire service.
The appliance may only be installed in a room that complies with the
requirements stated in national and local ventilation
regulations (1.3 "Regulations").
3.1 Introduction
This chapter describes the installation activities to be carried out before you
actually start using the appliance (9 "Starting and running"), namely:
• Packaging;
• Environmental conditions;
• Technical specifications;
• Water connections, Unvented;
• Water connections, Vented;
• Gas connection;
• Air supply and flue;
• Electrical connection;
• Checking the supply pressure and burner pressure;
In the event of conversion to a different gas category, see
conversion (4 "Conversion to a different gas category").
3.2 Packaging
To avoid damaging the appliance, remove the packaging carefully.
We recommend unpacking the appliance at or near its intended location.
Attention
The appliance may only be manoeuvred in an upright position. Take care
that the appliance is not damaged after unpacking.
3.3 Environmental
conditions
The appliance is suitable for either open or room-sealed combustion. If
installed as a room-sealed appliance, then the availability of the necessary
external air supply will depend on the place of installation. In this event, there
are no additional ventilation requirements.
If the appliance is to be installed as an open system, then it will be subject to
the guidelines and ventilation regulations that are in force locally.
The alternative installation types are B23, C13, C33, C43, C53 and C63.
Attention
The appliance may not be used in rooms where chemical substances are
stored or used, due to the risk of explosion and/or corrosion of the appliance.
Some propellants, bleaching agents, degreasing agents etc. disperse vapours
which are explosive and/or which cause accelerated corrosion. If the appliance
is used in a room in which such substances are present, the warranty will be
void.