A.O. Smith 160M Fan User Manual


 
18
OPERATING INSTRUCTIONS FOR I.I.D. MODELS
The I.I.D. models have an automatic intermittent spark ignition system, figure 3, mounted on the jacket at the front of the heater which
ignites the pilot gas whenever system controls call for heat.
Start the unit in accordance with the instructions on the operating label attached to the heater. These instructions are repeated in the
following.
1. SET THE THERMOSTAT TO LOWEST SETTING.
2. TURN OFF ALL ELECTRIC POWER TO THE APPLIANCE IF SERVICE IS TO BE PERFORMED.
3. TURN GAS VALVE CONTROL KNOB CLOCKWISE TO “OFF”. REFER TO STEP 5 OF “OPERATING INSTRUCTIONS”
ABOVE.
A. THIS APPLIANCE IS EQUIPPED WITH AN IGNITION
DEVICE WHICH AUTOMATICALLY LIGHTS THE
PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.
B. BEFORE OPERATING SMELL ALL AROUND THE
APPLIANCE AREA FOR GAS . BE SURE TO SMELL
NEXT TO THE FLOOR BECAUSE SOME GAS IS
HEAVIER THAN AIR AND WILL SETTLE ON THE
FLOOR.
WHAT TO DO IF YOU SMELL GAS
DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRIC SWITCH
DO NOT USE ANY PHONE IN YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM
A NEIGHBOR’S PHONE. FOLLOW THE GAS
SUPPLIER’S INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUPPLIER,
CALL THE FIRE DEPARTMENT.
C. USE ONLY YOUR HAND TO TURN THE GAS
CONTROL KNOB . NEVER USE TOOLS. IF THE KNOB
WILL NOT TURN BY HAND, DON’T TRY TO REPAIR
IT. CALL A QUALIFIED SERVICE TECHNICIAN.
FORCE OR ATTEMPTED REPAIR MAY RESULT IN A
FIRE OR EXPLOSION.
D. DO NOT USE THIS APPLIANCE IF ANY PART HAS
BEEN UNDER WATER. IMMEDIATELY CALL A
QUALIFIED SERVICE TECHNICIAN TO INSPECT THE
APPLIANCE AND TO REPLACE ANY PART OF THE
CONTROL SYSTEM AND ANY GAS CONTROL
WHICH HAS BEEN UNDER WATER.
E. DO NOT OPERATE APPLIANCE UNLESS UNIT IS
FILLED WITH WATER AND INLET LINES AFTER
FULLY OPEN.
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS
EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
1. STOP! READ THE SAFETY INFORMATION
ABOVE ON THIS LABEL.
2. SET THERMOSTAT TO LOWEST SETTING.
3. TURN OFF ALL ELECTRIC POWER TO THE
APPLIANCE.
4. THIS APPLIANCE IS EQUIPPED WITH AN IGNITION
DEVICE WHICH AUTOMATICALLY LIGHTS THE
PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.
5. TURN GAS VALVE CONTROL KNOB CLOCKWISE
TO “OFF” (FIG. A) A SLIGHT INDENT CAN BE FELT
IN THE “OFF” POSITION.
6. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS.
THEN SMELL FOR GAS, INCLUDING NEAR THE
FLOOR. IF YOU THEN SMELL GAS.
STOP! FOLLOW “B” IN THE SAFETY
INFORMATION ABOVE IN THIS LABEL.
IF YOU DON’T SMELL GAS. GO TO NEXT
STEP.
7. TURN GAS CONTROL KNOB COUNTERCLOCKWISE
TO “ON” (FIG. B) UNTIL KNOB SNAPS INTO “ON”
POSITION.
8. TURN ON ALL ELECTRICAL POWER TO THE
APPLIANCE.
9. SET THERMOSTAT TO DESIRED SETTING. PILOT
WILL BE IGNITED BY ELECTRONIC SPARK. WHEN
PILOT IGNITION IS SENSED, THE MAIN BURNERS
WILL IGNITE.
10. IF MAIN BURNER FAILS TO IGNITE, REMOVE
BURNER ACCESS DOOR AND FOLLOW SMALL
METAL TUBE FROM GAS VALVE TO PILOT. REPEAT
STEPS 2 THRU 9. MAKE SURE PILOT IS BURNING.
IF PILOT FAILS TO IGNITE, CHECK FOR PILOT
IGNITION SPARK.
IF APPLIANCE WILL NOT OPERATE, FOLLOW THE
INSTRUCTIONS “TO TURN OFF GAS TO
APPLIANCE” AND CALL YOUR SERVICE
TECHNICIAN OR GAS SUPPLIER.
FOR YOUR SAFETY READ BEFORE OPERATING
TO TURN OFF GAS TO APPLIANCE
OPERATING INSTRUCTIONS
HONEYWELL VR8304P GAS CONTROL