User Programming Mode
To enhance the flexibility of the Gardtec 350 control panel there are five user
programmable options available. When programming the user options the display is
via the five zone LEDs and the legend to the right of the LEDs is used (see
illustration below). It should be noted that User Programming Mode is only available
to Master level codes ( User Numbers 1, 4 and 5 please refer to user code
programming for more details).
Bold legend for normal use User programming mode legend
System Status LEDs
LED Modes
When programming the user options three LED states are possible.
User Programmable Options
Five User Programmable options are available, these are.
REMOVE
This option enables a Master user to Remove (turn off) individual zones when
setting the system. This is in addition to any part sets that may have been
programmed by the installation engineer. When this option is used it should be
noted that the selected zones will be removed for the one set only.