FAULT AND ALERT MESSAGES
Call the technical support phone number listed on the back cover for further technical assistance or to locate a qualied service technician
in your area.
POSSIBLE CAUSES - CHECK/REPAIR DISPLAYED FAULT/ALERT MESSAGE
The control system has failed to ignite the Main Burner.
Water heater is not properly grounded, loose or open ground wire
to the Main Burner.
Dirty/corroded ame sensor, clean ame sensor with ne steel
wool (replace if damaged).
Loose or open wiring to the ame sensor.
Loose or open wiring to the 24 V Gas Control Valve.
Supply gas turned off, low gas volume.
Intake air and/or vent piping is restricted or improperly installed.
Low or no manifold gas pressure to the Main Burner.
CHANGE BACK
ADVANCED
Ignition Failure
Fault occurred 2 mins ago
The water heater has failed to
ignite the burner.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)
The control system has detected the Blocked Exhaust Switch
contacts are open.
The condensate drain is blocked lling the exhaust elbow with
water - clear the condensate drain.
Loose or open wiring to the Blocked Exhaust Switch.
Restricted/blocked vent piping - condensate trapped in low point.
Excessive equivalent pipe length, exceeded the maximum number
of 90° elbows or wrong pipe size used in the vent piping system.
Excessive wind outdoors pressurizing the vent system piping.
Excessive negative air pressure in the installed space.
CHANGE BACK
ADVANCED
Blocked Exhaust
Fault occurred 2 mins ago
The exhaust is blocked or
restricted. Ensure
condensate hose is draining.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)