Amana 10730418 Heat Pump User Manual


 
8
OPERATING INSTRUCTIONS
1. Turn on the electrical power supply to the unit.
2. Place the room thermostat selector switch in the COOL or
HEAT position (or AUTO if available, and if automatic
changeover from cooling to heating is desired).
3. Set the room thermostat to the desired temperature.
MAINTENANMAINTENAN
MAINTENANMAINTENAN
MAINTENAN
CECE
CECE
CE
WARNING
T
O AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK,
DISCONNECT ELECTRICAL POWER BEFORE PERFORMAING ANY
MAINTENANCE.
REPLACING OR CLEANING FILTER
A return air filter is not supplied with this unit; however, there must be
a means of filtering all of the return air. The filter(s) may be located in
the return air duct(s), or return air filter grille(s). Consult with your
installing dealer for the actual location of the return air filter(s) for
your unit.
Dirty filters are the most common cause of inadequate heating or
cooling performance. Filter inspection should be made at least ev-
ery two months; more often if necessary because of local conditions
and usage.
Dirty throwaway filters should be discarded and replaced with a new,
clean filter. Dirty permanent filters should be washed with water, thor-
oughly dried and sprayed with a filter adhesive before being rein-
stalled. (Filter adhesives may be found at many hardware stores.)
Permanent filters should last several years; however, should one
become torn or uncleanable, it should be replaced.
MAINTAINING CABINET FINISH
Use a fine grade automotive wax on the cabinet finish to maintain
the finish’s original high luster. This is especially important in areas
with high ultraviolet radiation.
CLEAN OUTSIDE COIL (QUALIFIED SERVICER ONLY)
The coil with the outside air flowing over it should be inspected an-
nually and cleaned as frequently as necessary to keep the finned
areas free of lint, hair and debris.
CONDENSER AND EVAPORATOR MOTORS
Bearings on the evaporator motor and the condenser motor are per-
manently lubricated. No additional oiling is required.
WARNING
T
O AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK, DO
NOT REMOVE ANY INTERNAL COMPARTMENT COVERS OR ATTEMPT ANY
ADJUSTMENT.
CAUTION
V
ERIFY PROPER OPERATION AFTER SERVICING.
ACCESSOACCESSO
ACCESSOACCESSO
ACCESSO
RIESRIES
RIESRIES
RIES
Horizontal Duct Covers (CHK001A)
Single Point Power Connection (SPK**A)
Roof Curb - Heat Pump (PRC06A1)
Roof Curb - Universal (PRC08A1)
Over-Under to Side by Side (PDTROU6A)
Additional accessories, as described above, can be purchased to fit
specific application needs. Accessories can be ordered by the part
numbers in the table and each accessory includes its own separate
instructions.
REPLACEMENT PARTS
Refer to the description in the Parts Catalog when ordering any part.
Be sure to provide the unit model, manufacturing, and serial num-
bers with the order.
NOTE: Details for installing and wiring electric heater kits and single
point wiring kits are contained in the installation instructions for these
accessories.
2000-2004 Goodman Company, L.P.
Effective: May 2004