Nilfisk-ALTO SR 1301 B Vacuum Cleaner User Manual


 
USER MANUAL
ENGLISH
SR 1301 B 1463436000(1)2008-05 A
19
SCHEDULED MAINTENANCE TABLE
Procedure Upon delivery
Every 10
hours
Every 50
hours
Every
100
hours
Every
200
hours
Every
400
hours
Battery uid level check (1)
Side and main broom height check
Hopper hydraulic lifting system oil level check (1)
Skirt height and operation check
Panel dust lter cleaning and integrity check
Filter shaker operation check (*)
Driving wheel chain cleaning and tension check (*)
Visual inspection of the belt between motor and main broom (*)
Closed pocket lter cleaning and integrity check
Brake adjustment (*)
Nut and screw tightening check (*)(2)
Steering chain cleaning (*)
Vacuum system ef ciency check (*)
Replacement of the timing belt between idle gear and main broom (*)
Hopper gasket integrity check (*)
Lifted hopper control microswitch adjustment check (*)
Horizontal hopper control microswitch adjustment check (*)
Motor carbon brush check and replacement (*)
Hydraulic system oil change (*)(3)
(*) For the relevant procedure, see the Service Manual.
(1) Or before start-up.
(2) And after the rst 8 running-in hours.
(3) Change the hydraulic system oil for the rst time after 500 hours, then every 2,000 hours or every year.