Nilfisk-ALTO SR 1301 B Vacuum Cleaner User Manual


 
ENGLISH
USER MANUAL
10
1463436000(1)2008-05 A SR 1301 B
Electrical components Values
Electrical system voltage 24 V
Vacuum system motor 310 W, 3,000 rpm
Main broom motor 500 W, 550 rpm
Drive system motor 750 W, 315 rpm
Side broom reduction unit 90 W, 85 rpm
Filter shaker motor 90 W, 5700 rpm
Closed pocket lter shaker motor (optional) 110 W, 3,000 rpm
Batteries Values
Standard WET batteries with acid electrolyte, in serial connection Four 6 V 180 Ah batteries
Optional WET battery with acid electrolyte One 24 V 240 Ah battery
Optional WET or GEL batteries available at any Nil sk Retailer Total voltage 24 V
Battery maximum capacity 330 Ah
Battery case size (length x width x height) 800 x 300 x 150 mm
Battery compartment maximum size (width x length x height) 800 x 360 x 380 mm
Dust vacuuming and ltering Values
Paper dust lter 15-20 m 3.6 m
2
Main broom compartment vacuum 10.9 mm/H
2
O
Hopper hydraulic lifting system Values
Pump Parker 108 AE S32 - 24 V
Maximum pressure 110 Bar
Oil tank capacity 0.75 litres
Hydraulic circuit total capacity 1.4 litres
Hydraulic system oil (at ambient temperature above 10°C) AGIP Arnica 46 (*)
CAUTION!
If the machine is to be used at ambient temperatures below +10°C, the oil should be changed with equivalent oil
having a viscosity of 32 cSt. For temperatures below 0°C, use an oil with lower viscosity.
(*) See the oil technical data and reference data tables below.
TECHNICAL DATA REFERENCE DATA
AGIP ARNICA 46 32 ISO-L-HV
Viscosity at 40°C mm
2
/s 45 32 ISO 11158
Viscosity at 100°C mm
2
/s 7.97 6.40 AFNOR NF E 48603 HV
Viscosity index / 150 157 AISE 127
Flash point COC °C 215 202 ATOS Tab. P 002-0/I
Pour point °C -36 -36 BS 4231 HSE
Density at 15°C kg/l 0.87 0.865 CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA 22, 46, 68)
EATON VICKERS I-286-S3
EATON VICKERS M-2950
DIN 51524 t.3 HVLP
LAMB LANDIS-CINCINNATI P68, P69, P70
LINDE
PARKER HANNIFIN (DENISON) HF-0
REXROTH RE 90220-1/11.02
SAUER-DANFOSS 520L0463