AIRSTREAM LAND YACHT GAS
STEP 5
Action: Fill all tanks to the level that you want the monitor to report full. Maximum suggested is liquid
about 1 inch below the top of the tank and the maximum is 4 inches above the empty level. When all tanks
are set to the desired level press and release the status button 1 time.
Result: Display will go blank for a few moments while the full values are being read. When the system has
completed reading the full values Fresh Water, Gray Water 1, Gray Water 2, Black Water, and LP Gas will
light. All other LED’s will turn off. If a system has passed calibration the LED beside it will light Green.
If a system was not installed, the LED beside it will light
yellow and that system will not be reported in normal
operation. If a system fails calibration the LED beside it
will light red and that system will not be reported in normal
operation. In the event that a system fails calibration, turn off
the monitor and repeat calibration procedure. The most likely
cause for a failure is that the full level was not set the
minimum of 4 inches above the empty level. If all installed
systems display a green LED proceed to step 6.
In this example Fresh, Gray 1, and Black have passed
calibration. Gray Water 2 and LP Gas were not installed and
therefore they will not be reported in normal operation.
Display after completion of step 5.
On all diagrams the Letters R=Red, G=Green, Y=Yellow,
Blank=no LED lit.
STEP 6
Action: Remove the calibration decal on the lower 4 LED’s. Pre
ss and release status button 1 time.
esult: Display will turn red from empty to full 1 time, turn green from empty to full 1 time, and all flash
alibration is complete
R
green 1 time. Power on greeting will be played and installed tank levels will be displayed.
C
H-13