Agilent Technologies 6834B Air Conditioner User Manual


 
4 - Front Panel Operation
36
Press this key to access the harmonic menu list
Display Measurement
<reading>A I:MAG: <index> current harmonic magnitude
<reading>
°
I:PHASE: <index>
current harmonic phase
<reading>V V:MAG: <index> voltage harmonic magnitude
<reading>
°
V:PHASE: <index>
voltage harmonic phase
<reading> N:MAG: <index> neutral current harmonic magnitude
<reading>
°
N:PHASE: <index>
neutral current harmonic phase
<reading>
°
CURR:THD
current total % harmonic distortion
<reading>
°
VOLT:THD
voltage total % harmonic distortion
Output Control Keys
Output control keys control the output functions of the ac source.
Press this key to access the voltage menu list.
Display Command Function
VOLT <value>
Set immediate rms output voltage (
φ
)
VOLT:T<value>
Set triggered rms output voltage (
φ
)
VOLT:M <char>
Select the voltage mode (
φ
) (FIXED, STEP, PULSE or LIST)
RANGE <char>
Select the voltage range (
φ
) (150 or 300)
SLEW <value>
Set immediate voltage slew rate in volts/second (
φ
)
SLEW:T<value>
Set triggered voltage slew rate in volts/second (
φ
)
SLEW:M <char>
Select the voltage slew mode (
φ
) (FIXED, STEP, PULSE or LIST)
ALC <char> Select the voltage sense source (INT or EXT)
Press this key to access the current menu list.
Display Command Function
CURR:LEV <value> Set immediate rms output current limit
Press this key to access the frequency menu list.
Display Command Function
FREQ <value> Set immediate output frequency
FREQ:T<value> Set triggered output frequency
FREQ:M <char> Select the frequency mode (FIXED, STEP, PULSE or LIST)
SLEW <value> Set immediate frequency slew rate in volts/second
SLEW:T<value> Set triggered frequency slew rate in volts/second
SLEW:M <char> Select the frequency slew mode (FIXED, STEP, PULSE or LIST)
Notes:
φ = phase selectable on Agilent 6834B
reading = the returned measurement
index = a numeric value that represents the harmonic number from 0 to 50
char = a character string parameter
and scroll through the command list.
and scroll through the parameter list.
and specify the desired harmonic.
HarmonicShift
Voltage
Shift Current
Freq
Index Index