ADT Security Services Security System Home Security System User Manual


 
Ð 36 Ð
SUMMARY OF AUDIBLE/VISIBLE NOTIFICATIONS
(CUSTOM ENGLISH DISPLAY TOUCHPADS)
SOUND CAUSE DISPLAY
LOUD, INTERRUPTED*
Touchpad & External
FIRE ALARM. MANUALLY
ACTIVATED
FIRE is displayed;; zone number 95 is displayed
LOUD, CONTINUOUS*
Touchpad & External
BURGLARY/AUDIBLE
EMERGENCY ALARM.
ALARM is displayed. If programmed, descriptor of zone in alarm is also displayed.
ONE SHORT BEEP
(not repeated)
Touchpad only
a. SYSTEM DISARM.
b. SYSTEM ARMING ATTEMPT
ÊÊÊÊWITH AN OPEN ZONE..
c. BYPASS VERIFY.
a. DISARMED/READY TO ARM is displayed.
b. The number and descriptor of the open protection zone is displayed.
c. Numbers and descriptors of the bypassed protection zones are displayed (One
ÊÊÊÊbeep is heard for each zone displayed). Subsequently, the following is displayed:
ÊÊÊÊDISARMED BYPASS Ready to Arm.
ONE SHORT BEEP
(once every 40 seconds)
Touchpad only
a. SYSTEM IS IN TEST MODE.
b, LOW BATTERY AT A
ÊÊ TRANSMITTER.
a. Opened Zone identifications will appear.
b. LO BAT displayed with description of transmitter.
TWO SHORT BEEPS
Touchpad only
ARM AWAY. ARMED AWAY displayed. Red ARMED indicator lit.
THREE SHORT BEEPS
Touchpad only
a. ARM STAY OR INSTANT.
b. ZONE OPENED WHILE SYSTEM
ÊIS IN CHIME MODE.
a. ARMED STAY or ARMED INSTANT displayed. Red ARMED indicator lit.
b. CHIME displayed, descriptor of open protection zone will be displayed if the []
ÊÊÊÊkey is pressed.
RAPID BEEPING
Touchpad only
a. TROUBLE.
b. MEMORY OF ALARM.
c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRING FAIL.
a. CHECK displayed. Descriptor of troubled protection zone is displayed.
b.ALARM is displayed; descriptor of zone in alarm is displayed.
c. SYSTEM LO BAT displayed.
d. BELL FAILURE is displayed.
SLOW BEEPING
Touchpad only
a. EXIT DELAY WARNING (if
ÊÊÊÊprogrammed).
b. ENTRY DELAY WARNING.
a. ARMED AWAY is displayed along with You May Exit Now.
b. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the
ÊÊÊÊÊdelay time without disarming causes alarm.
* If a bell is used as external sounder, fire alarm is
pulsed ring;
burglary/audible emergency is
steady ring
.