ADT Security Services EZ Home Security System User Manual


 
17
Your ADT Safewatch EZ System is constantly monitoring its own components, as well as all critical services, such as AC power and
the telephone line, to insure that it is always ready to provide the protection for which it was designed. When a system trouble occurs, the
EZ Touchpad will caution you with a Trouble
TBL
light and a beeping sounder.
If you cannot immediately fix the trouble, the system can still be used. Simply press SILENCE to view the trouble as described below
and press SILENCE again to exit the VIEW TROUBLE mode. The system can now be armed.
To view the trouble, press
SILENCE
, count the number of Trouble
TBL
and
READY
flashes and refer to the following table. If there
is more than one trouble to view, press
SILENCE
again to scroll to the next trouble, and again to exit the VIEW TROUBLE mode. The
Trouble TBL light will remain pulsing as a reminder if the trouble is still present. NOTE: If EZ Touchpad siren chirps once every 10 sec-
onds, call for service.
SYSTEM TROUBLE ERROR CODES
TBL
Flashes /
Touchpad beeps
READY
Flashes
Trouble Condition Action
STEADY NONE Zones Bypassed This is a reminder that zones have been bypassed (by pressing
BYPASS
). If it is
necessary to bypass any inoperative zones, it is important to have the zones re-
paired as soon as possible.
1
NONE AC Power Failure This trouble will occur if AC power is not present. Make sure the system trans-
former is plugged into its AC receptacle and check the circuit breaker, otherwise
call for service.
2 NONE Low Battery If there has been a recent power failure, the battery may be partially depleted and
must be recharged by the control panel. If the trouble does not clear in 24 hours,
call for service.
3 NONE Communication
Failure
The system was not able to report to central station. If this is due to a temporary
interruption in the telephone service, the trouble can be cleared when the service
is restored by pressing
SILENCE
again.
4 NONE Telephone Line Cut The telephone line has failed. If telephone service has been temporarily inter-
rupted, the trouble will clear when restored. Otherwise, call for service.
5 NONE Bell/Siren Trouble There is a problem with the Bell or Siren. Call for service.