ADT Security Services 3000EN Home Security System User Manual


 
– 31 –
6HFXULW\&RGHV$XWKRULW\/HYHOV
&RQW
+RZ7R$VVLJQ8VHU&RGHVDQG$WWULEXWHV
The following lists the various command strings for adding user codes and attributes.
Refer to the User Setup chart at the back of this manual for factory
assignments of user attributes and to keep a record of user programming.
NOTE: Partition Master codes apply only to those user numbers previously assigned
(by the system master/installer) to the partition master’s partition.
Add User Code:
System/Partition Master code + [8] + user no.
+
new user’s code
(
Users 03/33 are preset
User 01 = installer User 03 = partition 1 master
to partition masters,
User 02 = master User 33 = partition 2 master
but can be changed.)
The Touchpad beeps once to confirm that new user was added.
Delete User Code:
System/Partition Master code + [8] + [user no.] + [#] [0]
The user code and all attributes* programmed for this user number,
including any associated RF keys, are erased from the system.
(*except assigned partition)
Authority Level:
System/Partition Master code + [8] + [user no.] + [#] [1]+ auth. level
Factory Assignments:
Authority Levels (see definitions on previous page):
users 04-32/34-49 = 0
0 = standard user 3 = duress
users 03/33 = 4
1 = arm only 4 = partition master
2 = guest
Access Group:
System/Partition Master Code + [8] + [user no.] + [#] [2]+ group (1-8)
Factory Assignments: none
You can assign users to a group, then set an access schedule that
defines the times this group of users can operate the system. The
system ignores these users outside the scheduled times.
User’s Partition:
System Master Code + [8] + [user no.] + [#] [3]+ 0 + partition(s) + [#]
Factory Assignments:
This command assigns the partitions the user can access. If more than
Part. 1 = users 03-32
one, enter partition numbers sequentially, then press [#] to end.
Part. 2 = users 33-49
E.g., master code + [8] + [user no.] + [#] [3] + [0] + [1] [2] + [#] gives
the user access to partitions 1 and 2 and the common partition.
Partition Entries: 1 = partition 1 and common
2 = partition 2 and common
3 = common partition only
RF User Number:
System/Partition Master Code + [8] + [user no.] + [#] [4]+ zone no.
Factory Assignments: none
Use this command to assign a wireless button device (keyfob) to this
user (keyfob must be enrolled in system first; see installer).
Z
one number: enter the zone number assigned to a button on the
keyfob that will be used for arming/disarming by this user.
Pager On/Off:
System/Partition Master Code + [8] + [user no.] + [#] [5] + 0 or 1
Factory Assignments:
You can program a user so that a message is sent to a pager
users 01-04 = 0 (off)
whenever this code is used to arm or disarm the system.
users 05-49 = 1 (on)
Paging On/Off: 1 = allow paging; 0 = no paging for this user