Admiral AAW-15CM1FHUE Air Conditioner User Manual


 
Because the compressor is located on the
controls side of the unit (right side), this side
will be heavier and more awkward to manipulate.
Inadequate support on control side of the unit
can result in personal injury and damage to your
unit and property. Therefore, it is recommended
to have someone assist you during the installation
of this unit.
E. Be certain the proper electrical outlet is within reach
of the installation. Use only a single outlet circuit rated
at proper current (see table 1 on page 4). All wiring
should be in accordance with local and national
electrical codes.
F. Your unit was designed to evaporate condensation
under normal conditions. However, under extreme
humidity conditions, excess condensation may cause
the basepan to overflow to the outside.
The unit should be installed where condensation
run-off cannot drip on pedestrians or neighboring
properties.
1. Select the Best Location
A. Your room air conditioner was designed to
fit easily into a single or double hung window. However,
since window designs vary, it may be necessary to
make some modifications for safe and proper
installation.
B. Make sure window and frame is structurally
sound and free from dry and rotted wood.
C. For maximum efficiency, install the air conditioner
on side of the house or building which favors more
shade than sunlight. If the unit is in direct sunlight,
it is advisable to provide an awning over the unit.
D. Provide sufficient clearance around the cabinet
to allow for ample air circulation through the unit.
See (Fig.B). The rear of the unit should be outdoors
and not in a garage nor inside of a building.
Keep unit as far away as possible from obstacles and
obstructions and at least 30" above the floor or
ground. Curtains and other objects within a room
should be prevented from blocking the air flow.
Awning
Window opening requirements
(see table below)
Side
obstruction
Ground
Fence,
wall, or
other
obstacle.
12" Min.
30" Min.
20"
Min.
20"
Min.
CAUTION
! !
Fig.B
Model
8K-10K
24
"
38"
41"
27
"
22.8" *15.7" *24.1"
12K
Size
Cabinet size
(W*H*D)
Min. Window
opening
Max. Window
opening
15-24K
26.5" *18.5" *26.9"
44"
30"
20.5" *14.8" *23.1"
8
INSTALLATION INSTRUCTIONS
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 10