3M 7624-T-110 Air Conditioner User Manual


 
4 78-8113-5099-6 Rev E
3.2 Position pre-formed ground braid with short tail over tape shield directly adjacent to cable jacket cut edge. PLEASE
NOTE: The ground braid needs to make full contact with the metallic tape shield. Position long tail of ground braid,
extending over cable jacket with solder block over mastic strip (Figure 3). Secure ground braid to cable jacket 4-1/2"
(114 mm) from cable semi-con edge using vinyl tape (Figure 3).
NOTE: Position vinyl tape with care, it also serves as a marker for positioning the termination.
Tape Shield
Ground Braid
Cable Jacket Edge
Vinyl Tape Marker
Semi-Con Edge
Solder Block
4-1/2" (114 mm)
1st Scotch
®
Mastic Strip 2230
Figure 3
3.3 Wrap ground braid around cable tape shield one complete wrap, trim excess to prevent overlap and secure in place
with constant force spring. Wrap spring in same direction as ground braid (Figure 4). Cinch (tighten) the spring after
wrapping the final winding.
3.4 Select second Scotch
®
Mastic Strip 2230 from kit and remove white release liners. Apply a second SINGLE WRAP
of mastic over solder block on ground braid and previously applied mastic (Figure 4). Cut off excess.
Tape Shield
Constant Force Spring
Ground Braid
Solder Block
Ground Braid Leg
Trim
Cable
Tape
Shield
1st Scotch
®
Mastic Strip 2230
2nd Scotch
®
Mastic Strip 2230
Figure 4