A SERVICE OF

logo

840569-YTG-A-0612
8 Johnson Controls Unitary Products
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
COIL
CFM RANGE
(MIN.-MAX.)
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
13 SEER AC COIL ONLY RATINGS
YCJD18S41S1(H)(E)
FC/MC/PC18 14.5,17.5 450-750 600 17.5 12.9 13.00 11.00
UC18 14.5,17.5 450-750 600 17.5 12.9 13.00 11.00
YCJD24S41S1(H)(E)
FC/MC/PC32 14.5 600-1000 800 24.0 16.7 13.00 11.00
FC/MC/PC35 17.5,21.0 600-1000 800 24.0 16.7 13.00 11.00
FC/MC/PC36 14.5,17.5,21.0 600-1000 800 24.0 16.7 13.00 11.00
FC/MC/PC37 14.5 600-1000 800 24.0 16.7 13.00 11.00
FC/MC/PC43 17.5,21.0 600-1000 800 24.0 16.7 13.00 11.00
UC36 14.5,17.5,21.0 600-1000 800 24.0 16.7 13.00 11.00
YCJD30S41S1(H)(E)
FC/MC/PC32 14.5 800-1200 1000 29.0 21.0 13.00 11.00
FC/MC/PC35 17.5,21.0 800-1200 1000 29.0 21.0 13.00 11.00
FC/MC/PC37 14.5 800-1200 1000 29.0 21.0 13.00 11.00
FC/MC/PC43 17.5,21.0 800-1200 1000 29.0 21.0 13.00 11.00
YCJD36S41S1(H)(E)
FC/MC/PC37 14.5 1000-1400 1200 35.0 24.8 13.00 11.00
FC/MC/PC43 17.5,21.0 1000-1400 1200 35.0 24.8 13.00 11.00
FC/MC/PC48 21.0,24.5 1000-1400 1200 35.0 24.8 13.00 11.00
UC48 21.0,24.5 1000-1400 1200 35.0 24.8 13.00 11.00
YCJD42S41S2(H)(E)
FC/MC/PC43 17.5,21.0 1200-1600 1400 41.5 29.8 13.00 11.00
FC/MC/PC48 21.0,24.5 1200-1600 1400 42.0 30.0 13.00 11.00
FC/MC/PC60 21.0,24.5 1200-1600 1400 41.5 29.6 13.00 11.00
FC/MC62 24.5 1200-1600 1400 42.0 30.4 13.00 11.00
FC64 24.5 1200-1600 1400 42.0 30.8 13.25 11.25
UC48 21.0,24.5 1200-1600 1400 42.0 30.0 13.00 11.00
YCJD48S41S1(H)(E)
FC/MC/PC48 21.0,24.5 1400-1800 1600 48.0 34.4 13.00 11.00
FC/MC/PC60 21.0,24.5 1400-1800 1600 48.0 34.4 13.00 11.00
UC48 21.0,24.5 1400-1800 1600 48.0 34.4 13.00 11.00
UC60 21.0,24.5 1400-1800 1600 48.0 34.4 13.00 11.00
YCJD60S41S1(E)
FC/MC/PC60 21.0,24.5 1600-2000 1800 57.0 38.5 13.00 11.00
FC/MC62 24.5 1600-2000 1800 57.0 38.5 13.00 11.00
FC64 24.5 1600-2000 1800 57.0 39.0 13.50 11.25
UC60 21.0,24.5 1600-2000 1800 57.0 38.5 13.00 11.00
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.