A SERVICE OF

logo

125
PARAMETERS
4
Setting method of the motor constants of the SF-HR type high efficiency motor and SF-
HRCA type inverter drive dedicated constant torque motor.
When offline auto tuning is enabled with motor running
1) Set Pr. 9 "electoronic thermal O/L relay", Pr. 80 "motor capacity", Pr. 81 "number of motor poles", Pr. 83
"rated motor voltage" and Pr. 84 "rated motor frequency" according to the motor.
2) Set "13" in Pr. 71. (offline auto tunning selection of constant torque motor)
3) Set "101" in Pr. 96 and perform offline auto tuning with motor running.
4) After completion of auto tuning, set "1" in Pr. 95.
5) Set "14" in Pr. 71 and "801" in Pr. 77.
6) Set the values in the following table in Pr. 85, Pr. 86 and Pr. 89.
7) Return the Pr. 77 setting to the original value.
When offline auto tuning is not enabled
(When the inverter capacity and the motor capacity are same)
1) Set Pr. 9 "electoronic thermal O/L relay", Pr. 80 "motor capacity", Pr. 81 "number of motor poles", Pr. 83
"rated motor voltage" and Pr. 84 "rated motor frequency" according to the motor.
2) Set "14" in Pr. 71 and "801" in Pr. 77.
3) Set the values in the following table in Pr. 85, Pr. 86 Pr. 89, Pr. 82, Pr. 90 to Pr. 94.
4) Set "1" in Pr. 95.
6) Return the Pr. 77 setting to the original value.
(Note) Though other parameter values can also be displayed when "801" is set in Pr. 77, they are
parameters for manufacturer setting and their values should not be changed. Note that changing
the settings may damage the inverter.
Type
Output
(kW)
Number
of
poles
Setting parameters Motor Constants
Pr.85
Excitation
current
refraction point
Pr.86
Excitation
current low
speed scale
factor
Pr.89
Speed
control
gain
Pr.82
Motor
excitation
current
Pr.90
R1
Pr.91
R2
Pr.92
L1
Pr.93
L2
Pr.94
X
SF-HR type motor constants
SF-HR 0.2 (Note 5) 4 10(9999) 130 100 1339 4580 4400 2048 2048 829
SF-HR 0.4 4 10(9999) 130 100 2171 2069 2045 1312 1312 804
SF-HR 0.75 4 10(9999) 130 100 2053 1458 1587 1392 1392 803
SF-HR 1.5 4 10(9999) 130 100 2456 884 902 1152 1152 790
SF-HR 2.2 4 10(9999) 130 100 2135 762 959 1328 1328 640
SF-HR 3.7 4 30
140 100 2356 894 639 1200 1200 656
SF-HR 5.5 4 30
140 120 2213 683 592 1280 1280 504
SF-HR 7.5 4 30
140 120 2010 735 518 1424 1424 454
SF-HR 11 4 10(9999) 130 100 2282 682 354 1248 1248 542
SF-HR 15 4 10(9999) 130 100 2190 654 361 1296 1296 486
SF-HR 18.5 4 30
140 120 1745 707 277 1632 1632 445
SF-HR 22 4 30
140 120 1745 707 277 1632 1632 445
SF-HR 30 4 20
150 120 1826 566 281 1568 1568 433
SF-HR 37 4 20
150 120 1408 631 279 2032 2032 406
SF-HR 45 4 20
140 120 1277 532 320 2240 2240 398
SF-HR 55 4 20
150 120 1684 499 227 1696 1696 429
SF-HRCA type motor constants
SF-HRCA 0.2 (Note 5) 4 10 (9999) 130 100 1348 4588 4409 2057 2057 839
SF-HRCA 0.4 4 10 (9999) 130 100 2181 2078 2052 1320 1320 813
SF-HRCA 0.75 4 10 (9999) 130 100 2063 1469 1596 1399 1399 810
SF-HRCA 1.5 4 10 (9999) 130 100 2465 893 913 1160 1160 796
SF-HRCA 2.2 4 10 (9999) 130 100 2145 771 968 1335 1335 649
SF-HRCA 3.7 4 30
140 100 2367 899 648 1209 1209 662
SF-HRCA 5.5 4 30
140 120 2223 689 601 1289 1289 514
SF-HRCA 7.5 4 30
140 120 2020 746 527 1433 1433 460
SF-HRCA 11 4 10 (9999) 130 100 2289 691 363 1256 1256 550
SF-HRCA 15 4 10 (9999) 130 100 2199 663 372 1303 1303 490
SF-HRCA 18.5 4 30
140 120 1755 716 286 1641 1641 451
SF-HRCA 22 4 30
140 120 1755 716 286 1641 1641 451
SF-HRCA 30 4 20
150 120 1835 577 290 1579 1579 440
SF-HRCA 37 4 20
150 120 1417 642 287 2040 2040 417
SF-HRCA 45 4 20
140 120 1285 540 329 2249 2249 406
SF-HRCA 55 4 20
150 120 1693 508 237 1705 1705 438