A SERVICE OF

logo

edge switch 2/16 service manual 2–31
Diagnostics
18
Both power supplies failed and must be removed and replaced (RRP: Power Supply
on page 4-4). Perform the data collection procedure after FRU removal and
replacement.
Did replacement of both power supplies solve the problem?
NO YES
The switch appears operational.
Contact the next level of support.
19
One or both power supplies appear operational, but the CTP card is not receiving DC
power. An in-card circuit breaker may have tripped due to a power surge or the CTP
card failed.
Reset the switch ("
Reset the Switch
" on page 3-36).
Did a switch reset solve the problem?
NO YES
The switch appears operational.
A CTP card failure is indicated. Because the CTP card is not a FRU, replace the
switch
20
Does the embedded web server interface appear operational?
NO YES
Go to step 22.
21
A Page cannot be found, Unable to locate the server, HTTP 404 - file not found,
or other similar message appears. The message indicates the web browser PC
cannot communicate with the switch because:
The switch-to-PC Internet (Ethernet) link could not be established.
AC power distribution in the switch failed, or AC power was disconnected.
The switch CTP card failed.
Go to step 12.