Disassembly & Assembly Disassembly and Assembly of Cleaning Mechanism 201
4.6.4 Pump ASSY
1. Remove the Maintenance ASSY.
(See p.199)
2. Remove the one central screw (M3
×
4) of the Pump ASSY and remove the three parts
including the gear.
(See Figure 4-76)
3. Remove the two screws (M3
×
6) on the gear side.
4. Disconnect the tube from the Cap ASSY, remove the one screw (M 3
×
6) and remove
the Pump ASSY.
(See Figure 4-77)
Figure 4-76. Removing the Pump ASSY 1/2
Figure 4-77. Removing the Pump ASSY 2/2
A D J U S T M E N T
R E Q U I R E D
Once you have replaced the Pump ASSY, execute “CLEAR
COUNTERS” (See p.71).