ZyXEL Communications 1111 Garage Door Opener User Manual


 
Z-Wave Series Programming Guide 16
CHAPTER 4
SHD2110/3110 Programming
4.1 Basic Command Class / Binary Switch Command Class
The SHD2110/3110 responds to BASIC and BINARY commands of the Z-Wave system.
4.1.1 BASIC_GET / BINARY_SWITCH_GET
When receiving the following commands from a Z-Wave Controller, the SHD2110/3110 will report
back its On/Off status:
4.1.2 BASIC_SET / SWITCH_BINARY_SET
When receiving the following commands from a Z-Wave Controller, the appliance(s) connected to
the SHD2110/3110 will turn on or off:
Basic Get Command
[Command Class Basic, Basic Get]
Basic Report Command
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]
Binary Switch Get Command
[Command Class Switch Binary, Switch Binary Get]
Binary Switch Report Command
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
Report ON:[Command Class Switch Binary, Switch Binary Report, Value =
(255)0xFF]
[Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached to the
Module turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to the
Module turns off.