Chapter 2 SHD1110 Programming
Z-Wave Series Programming Guide
11
Note: Once the SHD1110 is reset, it will be restored to its factory default status and
settings.
2.1.4 Auto Report
2.1.4.1 Time Interval
You can set the SHD1110 to automatically send out reports of its current status to Grouping 1 at a
set time. The time interval can be set from 1 minute to 24 hours. For instance, if time interval is set
to 1 minute, the SHD1110 will report its status once per minute.
Refer to parameter 6 of the Z-Wave Configuration Table.
2.1.4.2 Temperature Change
You can set the SHD1110 to automatically send out reports of temperature status to Grouping 1
once the temperature exceeds the set degree. The temperature difference range can be set from
1
o
C to 70
o
C. For instance, if the temperature is set to 28
o
C, the SHD1110 will report its current
temperature status once the temperature exceeds 28
o
C.
Refer to parameter 7 of the Z-Wave Configuration Table.
2.1.4.3 Humidity Change
You can set the SHD1110 to automatically send out reports of humidity status to Grouping 1 once
the humidity exceeds the set %RH. The humidity difference range can be set from 5%RH to
70%RH. For instance, if the temperature is set to 50%RH, the SHD1110 will report its current
humidity status once the humidity exceeds 50%RH.
Refer to parameter 8 of the Z-Wave Configuration Table.
Note: Auto report function may cause a lot of power consumption if it operates often.
Consider the actual requirements for enabling this function and setting the time
interval.
7Auto Report
(Temp.
Change)
11~70
or
0
Degree 0 / 0 Set auto report
temp. trigger interval
to be _ degree.
0: Disable auto
report
8Auto Report
(Humid.
Change)
15~70
or
0
% 0 / 0 Set auto report
humid. trigger
interval to be _ %.
0: Disable auto
report
Table 1 Z-Wave Configuration Table (continued)
PARAMETER FUNCTION SIZE (BYTE) VALUE UNIT
FACTORY
DEFAULT
DESCRIPTION