York YZE024 THRU 060 Heat Pump User Manual


 
Johnson Controls Unitary Products 27
246750-YTG-L-0408
Multipliers for determining the performance with other indoor sections.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO. YZE06011
INDOOR COIL MODEL NO. MC61D + MV20D
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1750 1850 1950
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 64.0 4.5 4.2 64.6 4.5 4.2 65.2 4.5 4.3
70 62.8 5.0 3.7 63.3 4.9 3.7 63.8 4.9 3.8
80 61.5 5.4 3.3 61.9 5.4 3.4 62.4 5.4 3.4
47
60 55.7 4.2 3.9 55.9 4.2 3.9 56.2 4.2 3.9
70 54.1 4.6 3.4 54.5 4.6 3.5 54.9 4.6 3.5
80 52.5 5.0 3.1 53.1 5.0 3.1 53.6 5.0 3.1
40
60 49.5 4.0 3.7 49.0 4.0 3.6 48.6 4.0 3.6
70 42.4 4.2 2.9 45.2 4.3 3.1 48.1 4.4 3.2
80 35.2 4.5 2.3 41.4 4.7 2.6 47.5 4.9 2.9
30
60 42.5 3.8 3.3 39.9 3.7 3.1 37.3 3.7 2.9
70 38.8 4.0 2.8 39.1 4.1 2.8 39.4 4.2 2.8
80 35.0 4.3 2.4 38.3 4.5 2.5 41.6 4.6 2.6
17
60 34.3 3.6 2.8 32.3 3.5 2.7 30.4 3.4 2.6
70 34.2 4.1 2.4 32.6 4.0 2.4 31.0 3.9 2.3
80 34.0 4.6 2.2 32.9 4.5 2.1 31.7 4.5 2.1
10
60 30.5 3.4 2.6 31.1 3.4 2.7 31.7 3.5 2.7
70 29.4 3.8 2.3 29.2 3.8 2.3 29.0 3.7 2.3
80 28.2 4.1 2.0 27.3 4.1 2.0 26.4 4.0 1.9
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
MBH KW COP
F*FV060 1.00 1.00 1.00
AV60 1.00 1.00 1.00
MV20D FC/MC60D 1.00 1.00 1.00
MV20D FC/MC62D 1.00 1.00 1.00
Variable Speed
Furnace
Coil
T.C. S.C. KW
P(C,V)9*D20 FC/MC/PC60D 0.99 0.99 1.00
P(C,V)9*D20 FC/MC62D 0.99 0.99 1.00
PV8*C20 FC/PC60C 0.99 0.99 1.00
P(C,V)9*C20 FC/PC60C 0.99 0.99 1.00
P(C,V)9*D20 HC60 0.99 0.99 1.00
PV8*C20 HD60 0.99 0.99 1.00
P(C,V)9*D20 HD60 0.99 0.99 1.00
P(C,V)9*D20 FC/MC62D 0.99 0.99 1.00
P(C,V)9*C20 UC60C 0.99 0.99 1.00
PV8*C20 UC60C 0.99 0.99 1.00
P(C,V)9*D20 UC60D 0.99 0.99 1.00