Multipliers for determining the performance with other indoor sections.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO. YZE03611
INDOOR COIL MODEL NO. FC/MC/PC48C + MV16C
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1100 1200 1300
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 37.7 2.6 4.3 38.4 2.5 4.5 39.1 2.4 4.7
70 36.7 2.8 3.8 37.2 2.7 4.0 37.8 2.7 4.1
80 35.7 3.0 3.4 36.0 3.0 3.6 36.5 2.9 3.7
47
60 34.5 2.4 4.2 34.3 2.4 4.3 34.2 2.3 4.3
70 32.9 2.7 3.6 33.0 2.6 3.7 33.2 2.6 3.8
80 31.3 2.9 3.1 31.7 2.9 3.2 32.1 2.8 3.3
40
60 30.4 2.3 3.8 30.7 2.3 3.9 31.0 2.3 4.0
70 29.3 2.6 3.3 29.8 2.5 3.4 30.4 2.5 3.5
80 28.3 2.9 2.9 29.0 2.8 3.0 29.7 2.8 3.1
30
60 25.6 2.2 3.4 24.6 2.1 3.4 23.7 2.0 3.4
70 25.7 2.5 3.0 25.1 2.4 3.0 24.5 2.4 3.0
80 25.9 2.8 2.7 25.6 2.7 2.8 25.3 2.7 2.8
17
60 20.8 2.1 2.9 20.9 2.1 2.9 21.0 2.1 2.9
70 19.9 2.3 2.5 20.8 2.4 2.6 21.8 2.4 2.7
80 18.9 2.6 2.2 20.7 2.6 2.3 22.6 2.7 2.5
10
60 19.3 2.1 2.7 19.7 2.1 2.7 20.1 2.1 2.8
70 17.9 2.4 2.2 19.1 2.4 2.4 20.3 2.4 2.5
80 16.4 2.6 1.9 18.5 2.6 2.1 20.5 2.6 2.3
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
MBH KW COP
AV36 1.00 1.00 1.00
AV48 1.01 1.00 1.01
MV12B FC/MC35B 1.00 1.00 1.00
MV12B FC/MC42B 1.00 1.00 1.00
MV16C FC/MC48C 1.00 1.00 1.00
MV12D FC/MC48D 1.00 1.00 1.00
Variable Speed
Furnace
Coil
T.C. S.C. KW
P(C,V)9*B12 FC/MC/PC35B 1.00 1.00 1.00
PV8*B16 FC/MC/PC35B 1.00 0.99 1.01
P(C,V)9*C16 FC/MC/PC35C 1.00 1.00 1.00
PV8*C16 FC/MC/PC35C 1.00 1.00 1.00
PV8*C20 FC/MC/PC35C 1.00 0.99 1.01
P(C,V)9*C20 FC/MC/PC35C 1.00 0.99 1.01
PV8*B16 FC/MC/PC42B 1.00 1.00 1.00
P(C,V)9*B12 FC/MC/PC42B 1.00 1.00 1.00
P(C,V)9*C20 FC/MC/PC42C 1.00 1.00 1.00
P(C,V)9*C16 FC/MC/PC42C 1.00 1.00 1.00
PV8*C16 FC/MC/PC42C 1.00 1.01 0.99
PV8*C20 FC/MC/PC42C 1.00 1.00 1.00
P(C,V)9*C20 FC/MC/PC48C 1.00 1.00 1.00
P(C,V)9*C16 FC/MC/PC48C 1.00 1.00 1.00
PV8*C16 FC/MC/PC48C 1.00 1.00 1.00
PV8*C20 FC/MC/PC48C 1.00 1.00 1.00
P(C,V)9*D20 FC/MC/PC48D 1.00 1.00 1.00
PV8*C16 HC42 1.00 1.00 1.00
PV8*C20 HC42 1.00 1.00 1.00
PV8*B16 UC42B 1.00 1.00 1.00
P(C,V)9*B12 UC42B 1.00 1.00 1.00
PV8*C20 UC42C 1.00 1.00 1.00
PV8*C16 UC42C 1.00 1.00 1.00
P(C,V)9*C16 UC42C 1.00 1.00 1.00
P(C,V)9*C20 UC42C 1.00 1.00 1.00
P(C,V)9*C20 UC48C 1.00 1.00 1.00
PV8*C20 UC48C 1.00 1.00 1.00
PV8*C16 UC48C 1.00 1.00 1.00
P(C,V)9*C16 UC48C 1.00 1.00 1.00
P(C,V)9*D20 UC48D 1.00 1.00 1.00
Variable Speed
Furnace
Coil
T.C. S.C. KW