York TCGD18 THRU 60 Air Conditioner User Manual


 
359315-YTG-B-0408
Johnson Controls Unitary Products 3
Additional R-410A Charge / Orifice Size for Various Matched Systems
Outdoor Unit
TCGD18
S41S1(H)
TCGD24
S41S1(H)
TCGD30
S41S1(H)
TCGD36
S41S1(H)
TCGD42
S41S1(H)
TCGD48
S41S1(H)
TCGD60
S41S1
Required Orifice or TXV
1,2
0.048 / 902 0.055 / 902 0.061 / 907 0.065 / 903 0.075 / 903 0.073 / 904 0.087 / 905
Factory Charge, lbs-oz 3 - 3 3 - 13 3 - 14 4 - 9 4 - 5 4 - 9 5 - 6
Indoor Coil
3,4
Additional Charge, Oz
FC/MC/PC/UC18A3X
48 + 0 ––––––
902 + 0 ––––––
FC/MC/PC/UC18B3X
48 + 0 ––––––
902 + 0 ––––––
FC/MC/PC32A3X
55 + 4 61 + 0 ––––
902 + 4 907 + 0 ––––
FC/MC/PC35B3X
55 + 4 61 + 0 ––––
902 + 4 907 + 0 ––––
FC/MC/PC35C3X
55 + 4 61 + 0 ––––
902 + 4 907 + 0 ––––
FC/MC/PC/UC36A3X
55 + 0 –––––
902 + 0 –––––
FC/MC/PC/UC36B3X
55 + 0 –––––
902 + 0 –––––
FC/MC/PC/UC36C3X
55 + 0 –––––
902 + 0 –––––
FC/MC/PC37A3X
55 + 4 61 + 2 65 + 0
902 + 4 907 + 2 903 + 0
FC/MC/PC43B3X
55 + 4 61 + 2 65 + 0 75 + 0
902 + 4 907 + 2 903 + 0 903 + 0
FC/MC/PC43C3X
55 + 4 61 + 2 65 + 0 75 + 0
902 + 4 907 + 2 903 + 0 903 + 0
FC/MC/PC/UC48C3X
65 + 8 75 + 2 73 + 4
903 + 8 903 + 2 904 + 4
FC/MC/PC/UC48D3X
65 + 8 75 + 2 73 + 4
903 + 8 903 + 2 904 + 4
FC/MC/PC/UC60D3X
–––––73 + 0 87 + 0
–––––904 + 0 905 + 0
FC/MC62D3X
––––––87 + 4
––––––905 + 4
HC18A3X
48 + 0 ––––––
902 + 0 ––––––
HC30A3X
55 + 0 –––––
902 + 0 –––––
HC36B3X
55 + 4 61 + 0 ––––
902 + 4 907 + 0 ––––
HC42C3X
55 + 4 61 + 2 65 + 0 75 + 0
902 + 4 907 + 2 903 + 0 903 + 0
HC60D3X
––––––87 + 0
––––––905 + 0
AHP18B3X
48 + 0 ––––––
902 + 0 ––––––
AHP30B3X
55 + 4 61 + 0 ––––
902 + 4 907 + 0 ––––
AHP36C3X
61 + 2 65 + 0
907 + 2 903 + 0
AHP42C3X
65 + 0 75 + 0
903 + 0 903 + 0