York H*RE024 Air Conditioner User Manual


 
036-21315-001 Rev. A (0502)
Unitary Products Group 5
* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
**
Refer to Quick Selection Chart for specific furnace match-up.
H2RE060S06
1650
2150
21,24 G1FA060S21,24 1900 53.5 37.1 - 13.25 12.00
24 G2FD060S24 1900 53.5 37.1 - 13.25 12.00
24 G2FD061H24 2050 54.5 39.1 - 13.25 12.10
- G1HD060 1900 52.5 36.0 - 13.00 11.75
24 G1NA060S24T 1900 53.0 35.9 - 13.00 11.90
21,24 G1UA060S21,24 1900 53.5 37.1 - 13.25 12.00
1. TXV = Use 1TV700 Series Kit.
COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued)
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER + TXV
W/O TDR
SEER + TXV
1
+ TDR*
EER
TOTAL SENS.
COOLING CAPACITY - With Variable Speed Furnaces
UNIT MODEL
VARIABLE SPEED
FURNACE MODEL
COIL MODEL
1
W
COOLING
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
2
EER
TOTAL SENS.
1 PH 14 SEER AC / P1DU / P1XD / P1XU - VARIABLE SPEED
3
H1RE024S06
P1DUA12V G1FA036S14 14 870 25.4 18.0 - 15.00 13.60
P1DUA12V G1UA036S14 14 870 25.4 18.0 - 15.00 13.60
P1DUA12V G2FD035S14 14 870 25.2 17.9 - 15.00 13.50
P1XDB12V G2FD030S17 17 830 26.0 17.9 - 15.00 13.65
P1XUB12V G1FA036S17 17 870 25.4 18.0 - 15.50 13.75
P1XUB12V G1UA036S17 17 870 25.4 18.0 - 15.50 13.75
P1XUB12V G2FD030S17 17 870 25.4 17.9 - 15.50 13.75
P1XUB12V G2FD036S17 17 870 25.8 18.1 - 15.50 13.90
H1RE030S06
P1DUA12V G1FA036S14 14 1000 28.8 20.0 - 13.50 12.50
P1DUA12V G1UA036S14 14 1000 28.8 20.0 - 13.50 12.50
P1DUB16V G2FD036S17 17 1000 30.0 20.7 - 14.50 13.35
P1XDB12V G2FD036S17 17 1040 30.2 20.7 - 14.00 12.50
P1XUB12V G2FD036S17 17 1020 29.2 20.7 - 14.00 12.65
H1RE036S06
P1DUB16V G2FD036S17 17 1200 34.4 24.5 - 14.00 12.70
P1DUC20V G1FA048S21 21 1200 36.2 25.3 - 15.50 14.15
P1DUC20V G1UA048S21 21 1200 36.2 25.3 - 15.50 14.15
P1DUC20V G2FD036S21 21 1200 34.6 24.8 - 14.65 13.05
P1DUC20V G2FD048S21 21 1200 36.0 25.7 - 15.50 13.95
P1XDB12V G2FD036S17 17 1130 34.8 24.5 - 14.20 12.60
P1XDD20V G2FD048S24 24 1195 36.2 25.7 - 14.50 13.10
P1XUB12V G2FD036S17 17 1200 34.4 24.5 - 14.00 12.65
H2RE042S06
P1DUC20V G1FA048S21 21 1400 39.5 28.4 - 14.50 12.45
P1DUC20V G1FA060S21 21 1400 41.0 29.6 - 15.00 12.80
P1DUC20V G1UA048S21 21 1400 39.5 28.4 - 14.50 12.45
P1DUC20V G1UA060S21 21 1400 41.0 29.6 - 15.00 12.80
P1DUC20V G2FD042S21 21 1400 39.5 28.2 - 14.00 12.30
P1DUC20V G2FD048S21 21 1420 40.0 28.9 - 14.50 12.60
P1DUC20V G2FD048S21 21 1420 40.0 28.9 - 14.50 12.50
P1XDD20V G2FD048S24 24 1365 41.0 28.9 - 14.40 12.50
P1XDD20V G2FD060S24 24 1420 41.5 33.8 - 14.40 12.55
H2RE048S06
P1DUC20V G1FA060S21 21 1605 46.5 33.9 - 14.00 12.20
P1DUC20V G1UA060S21 21 1605 46.5 33.9 - 14.00 12.20
P1DUC20V G2FD048S21 21 1605 45.5 33.2 - 13.50 12.00
P1XDD20V G2FD060S24 24 1580 47.0 33.9 - 13.80 12.20
H2RE060S06
P1XDD20V G2FD060S24 24 1580 52.5 34.3 - 13.50 12.2
P1DUC20V G1FA060S21 21 1630 53.0 34.9 - 13.60 12.4
P1DUC20V G1UA060S21 21 1630 53.0 34.9 - 13.60 12.4
P1XUC20V G1FA060S21 21 1590 53.0 34.5 - 13.50 12.4
P1XUC20V G1UA060S21 21 1590 53.0 34.5 - 13.50 12.4
P1XUD20V G1FA060S24 24 1560 53.0 34.4 - 13.75 12.5
P1XUD20V G1UA060S24 24 1560 53.0 34.4 - 13.75 12.5
P1XUD20V G2FD060S24 24 1560 53.0 34.4 - 13.75 12.5
P1XUD20V G2FD061H24 24 1560 53.5 34.9 - 14.00 12.8
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. TXV = Use 1TV700 Series Kit.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.