York HC Heat Pump User Manual


 
258931-BTG-A-0606
4 Unitary Products Group
Notes:
MC coils available with a factory installed horizontal drain pan option (H).
COOLING CAPACITY - Coil Only
*
MODEL
RATED
CFM
ENTERING
AIR °F
(Wet Bulb)
MBH @ Evaporator Temperature and Corresponding Pressure °F/ PSIG
35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0
HORIZONTAL DUCT TYPE
HD24A 815
72 35.3 32.4 28.7 24.9
67 32.6 29.4 26.0 22.5
62 26.7 23.7 20.5 17.2
57 21.7 18.8 15.7 12.3
HD36B 1192
72 57.9 52.7 47.1 41.5
67 46.4 41.1 35.9 30.4
62 36.2 30.4 26.5 24.7
57 31.1 28.7 26.5 24.7
HD48C 1610
72 83.4 71.7 59.7 47.1
67 66.8 56.1 45.6 34.9
62 52.1 41.5 33.7 28.3
57 44.7 39.2 33.7 28.3
HD60D 2100
72 133.0 112.4 90.9 69.2
67 106.5 87.9 69.4 50.0
62 83.0 65.0 51.3 41.1
57 71.2 61.4 51.3 41.1
* See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.
COOLING CAPACITY - COIL ONLY
*
Model
Rated
CFM
Entering Air °F
(Wet Bulb)
MBH @ EVAPORATOR TEMPERATURE AND
CORRESPONDING PRESSURE °F / PSIG
35/61.5 40/68.5 45/76.0 50/84.0
HC18A 600
72 26.4 24.0 21.5 18.6
67 24.3 22.0 19.4 16.8
62 20.0 17.7 15.3 12.9
57 16.1 14.0 11.8 9.2
HC30A 1000
72 42.7 38.9 34.7 30.6
67 34.3 30.3 26.5 22.5
62 26.7 22.5 24.5 19.8
57 22.9 21.2 19.6 18.3
HC36B 1200
72 73.4 63.1 52.5 41.5
67 58.8 49.3 40.2 30.7
62 45.8 36.4 29.7 24.8
57 39.3 34.4 28.1 23.2
HC42C 1400
72 84.9 73.0 60.1 48.1
67 68.0 58.9 46.5 35.6
62 53.1 42.2 34.4 28.8
57 45.5 40.0 32.0 26.7
HC60C 1800
72 112.8 95.0 77.0 58.4
67 90.3 74.5 58.8 43.1
62 70.3 55.1 43.4 34.9
57 60.4 52.1 40.4 31.9
* See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.