York HC Heat Pump User Manual


 
258931-BTG-A-0606
Unitary Products Group 11
DIMENSIONS
Coil - MC
Dimensions - MC Coils
Model A B C D
Refrigerant
Line Size
*
* Refrigerant line sizes may require larger lines for extended line lengths.
See York bulletin #690.01-AD1V for details.
Factory
Installed
TXV (R22)
Liquid Vapor
MC18A2AH1 14.5 22 13 3/8 13.5 3/8 3/4 2A
MC18A3XH1 14.5 22 13 3/8 13.5 3/8 3/4 None
MC18B2AH1 17.5 22 16 3/8 16.5 3/8 3/4 2A
MC18B3XH1 17.5 22 16 3/8 16.5 3/8 3/4 None
MC24A2AH1 14.5 26.5 13 3/8 13.5 3/8 3/4 2A
MC24A3XH1 14.5 26.5 13 3/8 13.5 3/8 3/4 None
MC24B2AH1 17.5 26.5 16 3/8 16.5 3/8 3/4 2A
MC24B3XH1 17.5 26.5 16 3/8 16.5 3/8 3/4 None
MC30A2AH1 14.5 26.5 13 3/8 13.5 3/8 3/4 2A
MC30A3XH1 14.5 26.5 13 3/8 13.5 3/8 3/4 None
MC30B2AH1 17.5 26.5 16 3/8 16.5 3/8 3/4 2A
MC30B3XH1 17.5 26.5 16 3/8 16.5 3/8 3/4 None
MC35B3XH1 17.5 22 16 3/8 16.5 3/8 3/4 None
MC35C3XH1 21 26.5 19 7/8 20 3/8 3/4 None
MC36A2AH1 14.5 26.5 13 3/8 13.5 3/8 7/8 2A
MC36A3XH1 14.5 26.5 13 3/8 13.5 3/8 7/8 None
MC36B2AH1 17.5 26.5 16 3/8 16.5 3/8 7/8 2A
MC36B3XH1 17.5 26.5 16 3/8 16.5 3/8 7/8 None
MC36C2AH1 21 26.5 19 7/8 20 3/8 7/8 2A
MC36C3XH1 21 26.5 19 7/8 20 3/8 7/8 None
MC42B2CH1 17.5 32 16 3/8 16.5 3/8 7/8 2C
MC42B3XH1 17.5 32 16 3/8 16.5 3/8 7/8 None
MC42C2CH1 21 32 19 7/8 20 3/8 7/8 2C
MC42C3XH1 21 32 19 7/8 20 3/8 7/8 None
MC48C2CH1 21 32 19 7/8 20 3/8 7/8 2C
MC48C3XH1 21 32 19 7/8 20 3/8 7/8 None
MC48D2CH1 24.5 32 23 3/8 23.5 3/8 7/8 2C
MC48D3XH1 24.5 32 23 3/8 23.5 3/8 7/8 None
MC60D2CH1 24.5 32 23 3/8 23.5 3/8 7/8 2C
MC60D3XH1 24.5 32 23 3/8 23.5 3/8 7/8 None
MC61D2CH1 24.5 36 23 3/8 23.5 3/8 7/8 2C
MC61D3XH1 24.5 36 23 3/8 23.5 3/8 7/8 None
All MC coils include a factory installed horizontal drain pan.
(3X) = Models require field installed TXV.
20 3/8”
(Opening)
A
C
3/4”Flange
B
22”
BOTTOM
OPENING
DIMENSIONS
D
201/4”
Coil - FC
Dimensions - FC Coils
Model A B C D
Refrigerant
Line Size
*
* Refrigerant line sizes may require larger lines for extended line lengths.
See York bulletin #690.01-AD1V for details.
Factory
Installed
TXV (R22)
Liquid Vapor
FC18A2AN1 14.5 18 13 3/8 13.5 3/8 3/4 2A
FC18A3XN1 14.5 18 13 3/8 13.5 3/8 3/4 None
FC18B2AN1 17.5 18 16 3/8 16.5 3/8 3/4 2A
FC18B3XN1 17.5 18 16 3/8 16.5 3/8 3/4 None
FC24A2AN1 14.5 22 13 3/8 13.5 3/8 3/4 2A
FC24A3XN1 14.5 22 13 3/8 13.5 3/8 3/4 None
FC24B2AN1 17.5 22 16 3/8 16.5 3/8 3/4 2A
FC24B3XN1 17.5 22 16 3/8 16.5 3/8 3/4 None
FC30A2AN1 14.5 22 13 3/8 13.5 3/8 3/4 2A
FC30A3XN1 14.5 22 13 3/8 13.5 3/8 3/4 None
FC30B2AN1 17.5 22 16 3/8 16.5 3/8 3/4 2A
FC30B3XN1 17.5 22 16 3/8 16.5 3/8 3/4 None
FC35B3XN1 17.5 22 16 3/8 16.5 3/8 3/4 None
FC35C3XN1 21 24.5 19 7/8 20 3/8 3/4 None
FC36A2AN1 14.5 24.5 13 3/8 13.5 3/8 7/8 2A
FC36A3XN1 14.5 24.5 13 3/8 13.5 3/8 7/8 None
FC36B2AN1 17.5 24.5 16 3/8 16.5 3/8 7/8 2A
FC36B3XN1 17.5 24.5 16 3/8 16.5 3/8 7/8 None
FC36C2AN1 21 24.5 19 7/8 20 3/8 7/8 2A
FC36C3XN1 21 24.5 19 7/8 20 3/8 7/8 None
FC42B2CN1 17.5 28 16 3/8 16.5 3/8 7/8 2C
FC42B3XN1 17.5 28 16 3/8 16.5 3/8 7/8 None
FC42C2CN1 21 28 19 7/8 20 3/8 7/8 2C
FC42C3XN1 21 28 19 7/8 20 3/8 7/8 None
FC48C2CN1 21 28 19 7/8 20 3/8 7/8 2C
FC48C3XN1 21 28 19 7/8 20 3/8 7/8 None
FC48D2CN1 24.5 28 23 3/8 23.5 3/8 7/8 2C
FC48D3XN1 24.5 28 23 3/8 23.5 3/8 7/8 None
FC60C2CN1 21 28 19 7/8 20 3/8 7/8 2C
FC60C3XN1 21 28 19 7/8 20 3/8 7/8 None
FC60D2CN1 24.5 28 23 3/8 23.5 3/8 7/8 2C
FC60D3XN1 24.5 28 23 3/8 23.5 3/8 7/8 None
FC coils are not available with a factory installed horizontal drain pan.
(3X) = Models require field installed TXV.
20 3/8”
(Opening)
A
C
3/4”Flange
B
22”
BOTTOM
OPENING
DIMENSIONS
D
201/4”