York HC Heat Pump User Manual


 
258931-BTG-A-0606
Unitary Products Group 3
COOLING CAPACITY - COIL ONLY
*
Model Coil Rated CFM
Entering Air °F
(Wet Bulb)
MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG
35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0
FULL-CASED “A” TYPE MULTI-POSITION
MC18A 550
72 25.8 23.5 21.0 18.2
67 23.7 21.5 19.0 16.4
62 19.5 17.3 14.9 12.6
57 15.8 13.5 11.5 9.0
MC18B 650
72 28.7 26.1 23.3 20.2
67 26.4 23.9 21.1 18.2
62 21.6 19.2 16.6 14.0
57 17.5 15.2 12.8 10.0
MC24A
MC24B
850
72 36.3 33.0 29.5 25.6
67 33.4 30.2 26.7 23.1
62 27.4 24.3 21.0 17.7
57 22.2 19.3 16.2 12.6
MC30A
MC30B
1025
72 41.5 37.8 33.7 29.5
67 36.2 32.4 28.6 24.5
62 29.1 25.3 24.0 19.2
57 24.1 21.5 18.7 15.8
MC35B
MC35C
1025
72 46.9 42.7 38.2 33.6
67 37.6 33.2 29.1 24.7
62 29.3 24.6 26.9 20.0
57 25.2 23.3 21.5 20.0
MC36A 1150
72 46.8 42.6 38.1 33.6
67 37.5 33.1 29.1 24.7
62 29.3 24.6 26.8 20.0
57 25.1 23.2 21.4 20.0
MC36B 1250
72 52.0 47.3 42.3 37.3
67 41.7 36.8 32.3 27.4
62 32.5 27.3 29.8 22.2
57 27.9 25.8 23.8 22.2
MC36C 1250
72 53.4 48.6 43.4 38.3
67 42.8 37.8 33.1 28.2
62 33.4 28.1 30.6 22.8
57 28.7 26.5 24.5 22.8
MC42B
MC42C
1400
72 88.4 76.0 63.3 50.0
67 70.8 59.4 48.4 37.0
62 55.2 43.9 35.8 29.9
57 47.4 41.5 35.8 29.9
MC48C
MC48D
1650
72 100.5 86.4 72.0 56.8
67 80.4 67.5 55.0 42.1
62 62.7 49.9 40.7 34.0
57 53.9 47.2 40.7 34.0
MC60D 1825
72 119.9 101.0 80.0 62.2
67 96.0 79.2 62.6 45.8
62 74.8 58.6 46.2 37.0
57 64.3 55.4 46.2 37.0
MC61D 2000
72 124.8 105.2 85.3 64.7
67 99.9 82.5 65.2 47.7
62 77.9 61.1 48.1 38.6
57 66.9 57.7 48.1 38.6
* See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.