332018-BTG-D-0208
Unitary Products Group 13
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HABE-F036S
INDOOR COIL MODEL NO. AHP42
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM 1000 1200 1400
ID DB 85 80 70 85 80 70 85 80 70
ID WB 72 67 57 72 67 57 72 67 57
75
T.C. 40.0 36.9 34.3 41.3 38.1 35.7 42.0 38.9 36.7
S.C. 25.4 24.4 23.4 27.6 26.3 25.5 29.6 27.9 27.2
K.W 1.98 1.96 1.94 1.99 1.97 1.95 2.00 1.98 1.96
85
T.C. 38.6 35.6 32.7 39.6 36.6 34.0 40.2 37.3 34.9
S.C. 24.8 23.8 22.8 27.0 25.8 24.9 29.1 27.6 26.6
K.W 2.21 2.18 2.17 2.22 2.19 2.18 2.23 2.20 2.19
95
T.C. 37.2 34.2 31.0 37.8 35.2 32.4 38.4 35.8 33.0
S.C. 24.2 23.3 22.3 26.4 25.3 24.2 28.5 27.2 25.9
K.W 2.44 2.41 2.40 2.45 2.42 2.41 2.46 2.42 2.42
105
T.C. 35.5 32.3 29.6 36.1 33.1 30.6 36.7 33.7 31.2
S.C. 23.5 22.6 21.7 25.6 24.6 23.5 27.6 26.5 25.3
K.W 2.75 2.72 2.72 2.75 2.73 2.72 2.76 2.73 2.73
115
T.C. 33.7 30.4 28.1 34.4 31.1 28.7 35.0 31.7 29.4
S.C. 22.8 21.8 21.1 24.7 23.9 22.8 26.8 25.8 24.6
K.W 3.06 3.04 3.03 3.06 3.04 3.02 3.07 3.04 3.03
125
T.C. 31.9 28.5 26.7 32.7 29.1 26.9 33.3 29.7 27.6
S.C. 22.2 21.1 20.5 23.9 23.1 22.1 25.9 25.1 24.0
K.W 3.37 3.36 3.34 3.37 3.35 3.32 3.38 3.35 3.33
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
AV36 – 1.00 1.01 0.97
MA14D FC/MC42D 0.99 1.01 1.06
MA14D FC/MC48D 1.00 1.02 1.07
MV16C FC/MC42C 1.00 1.01 0.97
MV16C FC/MC48C 1.02 1.02 0.97
– FC/MC/PC/UC37 1.00 1.00 1.00
– FC/MC/PC/UC42 0.99 1.01 1.06
– FC/MC/PC/UC43 1.00 1.00 1.00
– FC/MC/PC/UC48 1.00 1.02 1.07
– HC48 0.98 1.00 1.05
– HD48 0.99 0.99 1.06
Variable Speed
Furnace
Coil
T.C. S.C. KW
(F,L)L8V*A12 FC/MC/PC37A 1.00 0.98 0.97
FL9V*A12 FC/MC/PC37A 1.00 0.98 0.97
(F,L)L8V*B16 FC/MC/PC42B 1.00 0.98 0.97
(F,L)L8V*C16 FC/MC/PC42C 1.00 0.98 0.97
(F,L)L8V*B16 FC/MC/PC43B 1.00 0.98 0.97
(F,L)L8V*C16 FC/MC/PC43C 1.00 0.98 0.97
(F,L)L8V*C16 FC/MC/PC48C 1.02 1.01 0.97
(F,L)L8V*C16 HC48 1.00 0.98 0.97
(F,L)L8V*C16 HD48 1.00 0.98 0.97
(F,L)L8V*C20 FC/MC/PC42C 1.00 0.98 0.97
(F,L)L8V*C20 FC/MC/PC43C 1.00 0.98 0.97
(F,L)L8V*C20 FC/MC/PC48C 1.02 1.01 0.97
(F,L)L8V*C20 HC48 1.00 0.98 0.97
(F,L)L8V*C20 HD48 1.00 0.98 0.97
FL9(C,V)*B12 FC/MC/PC42B 1.00 0.98 0.97
FL9(C,V)*C16 FC/MC/PC42C 1.00 0.98 0.97
FL9(C,V)*B12 FC/MC/PC43B 1.00 0.98 0.97
FL9(C,V)*C16 FC/MC/PC43C 1.00 0.98 0.97
FL9(C,V)*C16 FC/MC/PC48C 1.01 1.00 0.97
FL9(C,V)*C16 HC48 1.00 0.98 0.97
FL9(C,V)*C16 HD48 1.00 0.98 0.97
FL9(C,V)*C20 FC/MC/PC42C 1.00 0.98 0.97
FL9(C,V)*C20 FC/MC/PC43C 1.00 0.98 0.97
FL9(C,V)*C20 FC/MC/PC48C 1.01 1.00 0.97
FL9(C,V)*C20 HC48 1.00 0.98 0.97
FL9(C,V)*C20 HD48 1.00 0.98 0.97
FL9(C,V)*D20 FC/MC/PC48D 1.01 1.00 0.97