York H4DH018 THRU 060 Air Conditioner User Manual


 
036-21020-003 Rev. C (0203)
Unitary Products Group 9
H4DH048S06
P1DUB16V G1FA048S17 17 1500 48.5 36.4 13.00 - 11.85
P1DUB16V G1UA048S17 17 1500 48.5 36.4 13.00 - 11.85
P1DUC20V G1FA048S21 21 1610 48.0 36.0 12.45 - 11.20
P1DUC20V G1FA060S21 21 1610 49.5 37.1 13.30 - 11.60
P1DUC20V G1HD048 - 1610 49.0 36.8 12.25 - 11.35
P1DUC20V G1UA048S21 21 1610 48.0 36.0 12.45 - 11.20
P1DUC20V G1UA060S21 21 1610 49.5 37.1 13.30 - 11.60
P1DUC20V G2FD048(S,H)21 21 1610 48.5 36.4 12.50 - 11.35
P1XDD20V G2FD048(S,H)24 24 1605 49.5 37.1 13.00 - 12.00
P1XUC16V G1FA048S21 21 1480 48.0 36.0 12.30 - 11.25
P1XUC16V G1FA060S21 21 1480 49.5 37.1 13.25 - 11.70
P1XUC16V G1UA048S21 21 1480 48.0 36.0 12.30 - 11.25
P1XUC16V G1UA060S21 21 1480 49.5 37.1 13.25 - 11.70
P1XUC16V G2FD048(S,H)21 21 1480 48.5 36.4 12.50 - 11.40
P1XUC20V G1FA048S21 21 1450 48.0 36.0 12.50 - 11.45
P1XUC20V G1FA060S21 21 1590 49.5 37.1 13.25 - 11.55
P1XUC20V G1UA048S21 21 1450 48.0 36.0 12.50 - 11.45
P1XUC20V G1UA060S21 21 1590 49.5 37.1 13.25 - 11.55
P1XUC20V G2FD048(S,H)21 21 1450 48.5 36.4 13.00 - 11.65
P1XUD20V G1FA060S24 24 1620 49.5 37.1 13.25 - 11.55
P1XUD20V G1UA060S24 24 1620 49.5 37.1 13.25 - 11.55
P1XUD20V G2FD048(S,H)24 24 1620 48.5 36.4 12.50 - 11.25
P1XUD20V G2FD060(S,H)24 24 1620 50.0 37.5 12.70 - 11.60
H4DH060S06
P1DUC20V G1FA060S21 21 1800 59.0 44.3 12.00 - 11.20
P1DUC20V G1HD060 - 1730 59.0 44.3 12.10 - 11.50
P1DUC20V G1UA060S21 21 1800 59.0 44.3 12.00 - 11.20
P1XDD20V G2FD060(S,H)24 24 1675 58.5 43.9 12.00 - 11.05
P1XUC20V G1FA060S21 21 1860 59.0 44.3 12.00 - 11.20
P1XUC20V G1UA060S21 21 1860 59.0 44.3 12.00 - 11.20
P1XUD20V G1FA060S24 24 1860 59.0 44.3 12.00 - 11.20
P1XUD20V G1UA060S24 24 1860 59.0 44.3 12.00 - 11.20
P1XUD20V G2FD060(S,H)24 24 1860 59.0 44.3 12.00 - 11.20
P1XUD20V G2FD061H24 24 1800 60.0 45.0 12.60 - 11.50
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. TXV = Use 1TV700 Series Kit.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
COOLING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT MODEL
VARIABLE SPEED
FURNACE MODEL
COIL MODEL
1
W
COOLING
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
2
EER
TOTAL SENS.