York H4DH018 THRU 060 Air Conditioner User Manual


 
036-21020-003 Rev. C (0203)
4 Unitary Products Group
- = Not applicable
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING
MODEL
ELECTRIC
2
HEAT KW
2. Single phase units require single phase 2HK heaters.
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
3. TXV = Use 1TV700 Series Kit.
EER
TOTAL SENS.
1 PH 12 SEER AC / N1AH + G2FD
H4DH018S06
N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 650 18.6 14.0 12.50 - 10.80
N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 650 19.0 14.3 12.50 - 10.80
H4DH024S06
N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 850 23.4 17.6 12.10 - 10.90
N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 850 23.4 17.6 12.00 - 10.90
H4DH030S06
N1AHB1206 5,8,10,15,19 17 G2FD030(S,H)17 1030 29.4 22.1 - 12.40 10.50
N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1030 30.0 22.5 12.40 - 10.60
H4DH036S06
N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1200 35.8 26.5 12.15 - 11.20
N1AHB1206 5,8,10,15,19 17 G2FD046(S,H)17 1200 36.2 26.8 12.30 - 11.20
N1AHD1406 5,8,10,15,19 24 G2FD048(S,H)24 1200 38.0 28.1 13.50 - 12.05
N1AHD1406 5,8,10,15,19 24 G2FD060(S,H)24 1200 38.5 28.5 13.70 - 12.20
H4DH042S06
N1AHC1606 5,8,10,15,20 21 G2FD042(S,H)21 1400 40.5 30.4 12.00 - 10.60
N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1400 42.0 31.5 12.35 - 10.90
H4DH048S06
N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1600 48.5 36.4 12.35 - 11.15
N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1600 50.0 37.5 12.50 13.00 11.45
H4DH060S06
N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1800 58.5 43.9 12.00 12.50 11.05
N1AHD2006 8,10,15,20,25,30 24 G2FD061H24 2000 60.0 45.0 12.50 12.50 11.25
1 PH 12 SEER AC / N1VS - VARIABLE SPEED
H4DH018S06 N1VSB12 10,15,18 17 G2FD024(S,H)17 650 20.0 15.0 - 13.50 11.20
H4DH024S06
N1VSB12 10,15,18 17 G2FD024(S,H)17 850 24.4 18.3 13.50 - 12.10
N1VSB12 10,15,18 17 G2FD036(S,H)17 860 24.6 18.5 13.55 - 12.10
H4DH030S06
N1VSB12 10,15,18 17 G2FD036(S,H)17 1030 31.0 23.3 13.40 - 11.30
N1VSB12 10,15,18 17 G2FD046(S,H)17 1000 32.6 22.8 13.50 - 11.50
H4DH036S06
N1VSB12 10,15,18 17 G2FD036(S,H)17 1200 35.6 26.7 13.10 - 12.05
N1VSC16 10,15,18 21 G2FD048(S,H)21 1200 38.0 28.5 14.10 - 12.55
H4DH042S06 N1VSC16 10,15,18 21 G2FD048(S,H)21 1380 42.5 31.9 13.35 - 11.70
H4DH048S06
N1VSC16 10,15,18 21 G2FD048(S,H)21 1590 49.0 36.8 13.00 - 11.70
N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1600 50.5 37.9 13.10 - 11.90
H4DH060S06
N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1780 59.0 44.3 12.40 - 11.40
N1VSD20 10,15,18,30 24 G2FD061H24 1780 60.5 45.4 - 13.00 11.80
1 PH 12 SEER AC / F2RP / RC / FP / FC / FV
4,5
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
H4DH018S06
F2RC/FC024 5,8,10 18 - 650 18.6 14.0 12.20 - 10.90
F2RP/FP018 2,5,8 18 - 650 18.0 13.5 12.00 - 10.70
F2RP/FP024 5,8,10 18 - 650 18.6 14.0 12.50 - 11.00
H4DH024S06
F2RC/FC024 5,8,10 18 - 850 23.0 17.3 12.00 - 10.80
F2RC/FC030 5,8,10,15 18 - 850 23.4 17.6 12.00 - 10.90
F2RP/FP024 5,8,10 18 - 850 24.0 18.0 12.10 - 10.90
F2RP/FP030 5,8,10,15 18 - 850 24.4 18.3 12.00 - 10.80
F2FP040 5,8,10,15 21 - 850 24.8 18.6 - 12.70 11.30
H4DH030S06
F2RC/FC030 5,8,10,15 18 - 1030 28.4 21.3 12.00 - 10.50
F2RP/FP030 5,8,10,15 18 - 1030 30.0 22.5 12.30 12.50 10.50
F2RP/FP036 5,8,10,15,19 21 - 1030 31.0 23.3 12.50 - 10.60
F2FP048 5,8,10,15,20,25 24 - 1030 31.4 23.6 12.60 - 10.70
H4DH036S06
F2RC/FC036 5,8,10,15 21 - 1200 35.6 26.7 12.35 - 11.10
F2RP/FP036 5,8,10,15,19 21 - 1200 36.2 27.2 12.50 - 11.45
F2RP/FP042 5,8,10,15 21 - 1200 36.4 27.3 12.50 - 11.50
F2FP045 5,8,10,15 24 - 1200 38.0 28.5 - 13.50 12.20
F2FP048 5,8,10,15,20,25 24 - 1200 36.8 27.6 12.80 - 11.80
H4DH042S06
F2RP/FP042 5,8,10,15 21 - 1400 40.5 30.4 12.00 - 10.50
F2FP045 5,8,10,15 24 - 1400 42.5 31.9 13.00 - 11.20
F2FP048 5,8,10,15,20,25 24 - 1400 41.5 31.1 12.20 - 10.65
H4DH048S06
F2FP048 5,8,10,15,20,25 24 - 1600 48.0 36.0 12.00 - 11.00
F2FP060 5,8,10,15,20,25 24 - 1600 49.0 36.8 12.30 - 10.95
F2FV060 8,10,15,20,25 24 - 1600 50.5 37.9 13.10 - 11.90
H4DH060S06
F2FP060 5,8,10,15,20,25 24 - 1900 59.0 44.3 12.00 - 10.90
F2FV060 8,10,15,20,25 24 - 1780 59.0 44.3 - 12.40 11.40
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.