FILTER PERFORMANCE
The airflow capacity data published in the “Blower Perfor-
mance” table listed above represents blower performance
WITHOUT filters. To determine the approximate blower per-
formance of the system, apply the filter drop value for the fil-
ter being used or select an appropriate value from the “Filter
Performance” table shown below.
NOTE: The filter pressure drop values in the “Filter Perfor-
mance” table shown below are typical values for the type of
filter listed and should only be used as a guideline. Actual
pressure drop ratings for each filter type vary between filter
manufacturer.
NOTES:
1. Air velocity through throwaway type filters may not exceed 300
feet per minute. All velocities over this require the use of high
velocity filters.
2. Air flows above 1800 CFM require either return from two sides or
one side plus bottom.
RECOMMENDED FILTER SIZES
Nominal CFM Cabinet Size Side Return Filter in.
Bottom Return
Filter in. (cm)
1200 A 16 x 25 14 x 25
1200 B 16 x 25 16 x 25
1600 C 16 x 25 20 x 25
2000 C 16 x 25 20 x 25
2000 D (2) 16 x 25 22 x 25
FILTER PERFORMANCE - PRESSURE DROP INCHES W.C.
Airflow Range
Minimum Opening Size
Filter Type
Disposable WASHABLE FIBER Pleated
1 Opening 2 Openings 1 Opening 2 Opening 1 Opening 2 Opening 1 Opening 2 Opening
Sq. in. Sq. in. In w.c. In w.c. In w.c. In w.c. In w.c. In w.c.
0 - 750 230
0.01 0.01 0.15
751 - 1000 330 0.04 0.03 0.20
1001 - 1250 330 0.08 0.07 0.20
1251 - 1500 330 0.08 0.07 0.25
1501 - 1750 380 658 0.14 0.08 0.13 0.06 0.30 0.17
1751 - 2000 380 658 0.17 0.09 0.15 0.07 0.30 0.17
2001 & Above 463 658 0.17 0.09 0.15 0.07 0.30 0.17
UNIT CLEARANCES TO COMBUSTIBLES
Application
Top Front Rear Left Side Right Side Flue
Floor/
Bottom
Closet
Alcove
Attic
In. In. In. In. In. In.
Upflow 1 3 0 0 0 0 Combustible Yes Yes