York GY9S-UP Furnace User Manual


 
Johnson Controls Unitary Products 3
277805-YTG-A-1106
Nominal external static pressure is 0.50” w.c. at furnace outlet ahead of cooling coils.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
ELECTRICAL AND PERFORMANCE DATA
Model
Input/
Cabinet
Output
Nominal
Airflow
Cabinet
Width
Total Unit AFUE Air Temp. Rise
MBH MBH CFM In. Amps % °F
GY9S040A12UP11 40/A 38 1200 14-1/2 9 94.0 35 - 65
GY9S060B12UP11 60/B 56 1200 17-1/2 9 92.0 40 - 70
GY9S080B12UP11 80/B 74 1200 17-1/2 9 92.0 45 - 75
GY9S080C16UP11 80/C 75 1600 21 12 92.0 45 - 75
GY9S080C20UP11 80/C 75 2000 21 14 92.0 40 - 70
GY9S100C16UP11 100/C 93 1600 21 12 92.0 45 - 75
GY9S100C20UP11 100/C 93 2000 21 14 92.0 40 - 70
GY9S120D20UP11 120/D 112 2000 24-1/2 14 92.0 40 - 70
GY9S135D20UP11 135/D 127 2000 24-1/2 14 92.0 45 - 75
Model
Input/
Cabinet
Max.
Outlet
Air Temp.
Blower
Blower
Size
Max.
Over-current
Protect
Min. Wire Size
(awg) @ 75 ft.
One Way
Operating
Wt
MBH °F HP Amps In. Lbs.
GY9S040A12UP11 40/A 165 1/2 7.0 11 x 8 20 14 119
GY9S060B12UP11 60/B 170 1/2 7.0 11 x 8 20 14 133
GY9S080B12UP11 80/B 175 1/2 7.0 11 x 8 20 14 140
GY9S080C16UP11 80/C 175 3/4 10.2 11 x 10 20 14 155
GY9S080C20UP11 80/C 170 1 12.7 11 x 11 20 12 157
GY9S100C16UP11 100/C 175 3/4 10.2 11 x 10 20 14 160
GY9S100C20UP11 100/C 170 1 12.7 11 x 11 20 12 162
GY9S120D20UP11 120/D 170 1 12.7 11 x 11 20 12 178
GY9S135D20UP11 135/D 175 1 12.7 11 x 11 20 12 178