York E*BD-(T Heat Pump User Manual


 
246819-BTG-H-0208
14 Unitary Products Group
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - Upflow Furnace Coils
UNIT
MODEL*
COIL
1
MODEL
ARI HEATING
2
47°F17°FHSPF
MBH COP KW MBH COP KW STD
EABD-F018S
FC/MC/PC/UC18 18.0 3.62 1.46 10.5 2.28 1.35 8.00
HC18 17.93.601.4610.42.281.348.00
EABD-F024S
FC/MC/PC/UC24 23.0 3.44 1.96 13.1 2.30 1.67 8.00
FC/MC/PC/UC30 23.0 3.44 1.96 13.1 2.30 1.67 8.00
HC30 23.03.421.9713.02.281.678.00
HD24 23.03.441.9613.12.301.678.00
EABD-F030S
FC/MC/PC35 30.03.662.4816.22.222.148.00
FC/MC/PC/UC/42 30.0 3.66 2.48 16.2 2.22 2.14 8.00
HC36 30.03.662.4816.12.222.128.00
HD36 30.03.662.4816.22.222.148.00
EABD-(T,W)030S
FC/MC/PC35 29.03.662.3215.73.661.258.00
FC/MC/PC/UC/42 29.0 3.66 2.32 15.7 3.66 1.25 8.00
HC36 29.03.662.3215.63.661.248.00
HD36 29.03.662.3215.73.661.258.00
EABD-F036S
FC/MC/PC35 34.43.442.9320.42.502.398.40
FC/MC/PC/UC/42 34.4 3.44 2.93 20.4 2.50 2.39 8.40
FC/MC/PC/UC/48 36.0 3.86 2.73 22.4 2.78 2.36 9.00
HC42 35.83.862.7222.42.782.369.00
HD36 36.03.862.7322.42.782.369.00
EABD-(T,W)036S
FC/MC/PC35 34.03.662.7220.23.661.618.00
FC/MC/PC/UC/42 34.0 3.66 2.72 20.2 3.66 1.61 8.00
FC/MC/PC/UC/48 35.0 3.66 2.80 21.8 3.66 1.74 8.00
HC42 35.03.662.8021.93.661.758.00
HD36 36.03.662.8822.43.661.798.00
EABD-F042S
FC/MC/PC/UC48 42.0 3.62 3.40 25.0 2.56 2.86 8.50
HD48 41.53.623.3625.02.562.868.50
EABD-(T,W)042S
FC/MC/PC/UC48 41.0 3.66 3.28 24.4 3.66 1.95 8.00
HD48 40.53.663.2424.43.661.958.00
EABD-F048S
FC/MC/PC/UC60 48.0 3.50 4.02 29.6 2.34 3.71 8.00
HC60 48.03.504.0229.62.343.718.00
HD60 48.03.504.0229.62.343.718.00
MC61 48.03.504.0229.62.343.718.00
EABD-(T,W)048S
FC/MC/PC/UC60 47.0 3.66 3.76 29.0 3.66 2.32 8.00
HC60 47.03.663.7629.03.662.328.00
HD60 47.03.663.7629.03.662.328.00
MC61 47.03.663.7629.03.662.328.00
EABD-F060S
FC/MC/PC/UC60 58.0 3.52 4.83 35.0 2.32 4.42 8.00
HC60 57.53.504.8134.82.304.438.00
HD60 58.03.524.8335.02.324.428.00
MC61 58.03.524.8335.02.324.428.00
EABD-(T,W)060S
FC/MC/PC/UC60 57.0 3.66 4.56 34.4 3.66 2.75 8.00
HC60 56.53.664.5234.23.662.738.00
HD60 57.03.664.5634.43.662.758.00
MC61 57.03.664.5634.43.662.758.00
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.