enthalpy to determine the most economical mix. Single
Enthalpy sensor also required.
PRESSURE SWITCH UPGRADE KIT - Contains screw in
type High pressure, Low Pressure/Loss of Charge switch,
freeze protection switch and lockout relay. Switches are
placed onto existing scharder ports located in the unit by fur-
nished adapters. When abnormal conditions are sensed
through the pressure switches, the unit will lock out prevent-
ing any further operation until reset or problem is corrected.
Package agency approved.
HAIL GUARD KIT - Kit contains protective grilles made of
expanded aluminum with full perimeter frame. Sloped hoods
are also included to assure maximum protection.
ANTI SHORT CYCLE TIMER - Automatically prevents the
compressor from restarting for 5 minutes after cycled off.Not
required if Thermostat 2ET07700224 and 2ET04700224 are
used.
FILTER / FRAME KIT (Single Phase only) - Kit contains the
necessary hardware to field install return air filters into the
base unit. Pre-cut filter racks and appropriate cleanable stan-
dard size filters are shipped in one kit. The filter rack is suit-
able for either 1" or 2" filters. (1" filter is supplied) This kit is
available for single phase horizontal or vertical duct applica-
tion only. Standard in all 3 Phase models.
MOTORIZED FRESH AIR DAMPER - Designed for duct
mounted side supply/return and unit mounted down supply/
return applications. Damper capable of providing 0% through
50% of outdoor air (field supplied). Closes on power loss,
includes hood and screen assembly.
RECTANGLE TO ROUND ADAPTERS - Kit includes one
supply and one return air rectangle to round duct adapter.
Adapters are preformed and designed to fit over current duct
openings on the base unit. Transition is from side square duct
opening to 14" round duct opening.
ROOF CURBS - NRCA approved curbs provide proper fit to
base unit for rooftop installations. Curbs are designed to be
assembled through hinge pins in each corner. Kit also pro-
vides seal strip to assure a water tight seal. 8 and 14 inch
high roof curbs are available.
MANUAL OUTDOOR DAMPER - Provides 0% through 50%
outdoor air capability (field adjustable). Designed for duct
mounted side supply/return applications. Includes hood and
screen assembly.
WALL THERMOSTAT - The units are designed to operate
with 24-volt electronic and electro-mechanical thermostats.
All units can operate with single stage heat / single stage cool
thermostats - with or without the economizer.
LOW AMBIENT KIT - Kit provides necessary hardware to
convert unit to operate in cooling cycle down to 0º F. Stan-
dard unit operation 45º F.
TRANSFORMER KIT - Kit provides necessary hardware to
provide single phase models from factory furnished 40 VA
transformer capability to 75 VA transformer capability.
(Required on installations with economizer or motorized
damper.)