York DNP042 Air Conditioner User Manual


 
036-21366-007-A-1205
Unitary Products Group 17
TABLE 11: BOTTOM SUPPLY AIR BLOWER PERFORMANCE - 208/230 VOLTS
1
MODEL #
DNP
MODE
(COOLING / HEATING)
CFM
EXTERNAL STATIC PRESSURE - IWG
.20 .30 .40 .50 .60 .70 .80 .90 1.0
WATTS WATTS WATTS WATTS WATTS WATTS WATTS WATTS WATTS
030
COOLIN G
(FACTORY SETTING)
1000 248 298 325 365 385 411 470 498 500
030
COOLIN G
(FIELD SETTING)
1250 342 385 431 474 510 562 614 657 694
030
HEATING (2 TUBE)
(FACTORY SETTING)
850 169 217 237 278 302 334 374 401 431
030
HEATING (3 TUBE)
(FACTORY SETTING)
1100 300 338 378 416 447 493 539 576 609
036
COOLING
(FACTORY SETTING)
1200 354 396 436 511 548 599 641 677 721
036
COOLIN G
(FIELD SETTING)
1350 442 503 563 606 648 685 721 774 826
036
HEATING (2 TUBE)
(FACTORY SETTING)
700 207 231 254 298 320 349 - - -
036
HEATING (3 TUBE)
(FACTORY SETTING)
1250 383 432 478 543 581 628 - - -
036
HEATING (4 TUBE)
(FACTORY SETTING)
1350 442 503 563 606 648 685 - - -
042
COOLIN G
(FACTORY SETTING)
1350 410 457 504 575 646 687 729 780 830
042
COOLIN G
(FIELD SETTING)
1500 450 500 553 641 729 798 830 872 939
042
HEATING (3 TUBE)
(FACTORY SETTING)
1500 450 500 553 641 729 798 830 872 939
042
HEATING (4 TUBE)
(FACTORY SETTING)
1275 388 433 478 545 612 652 691 739 787
048
COOLIN G
(FACTORY SETTING)
1400 427 476 525 599 673 716 759 812 865
048
COOLIN G
(FIELD SETTING)
1600 476 532 587 687 786 872 958 994 1030
048
HEATING (3 TUBE)
(FACTORY SETTING)
1525 458 511 564 654 744 814 - - -
048
HEATING (4 TUBE)
(FACTORY SETTING)
1600 476 532 587 687 786 872 - - -
048
HEATING (5 TUBE)
(FACTORY SETTING)
1600 476 532 587 687 786 872 - - -
060
COOLIN G
(FACTORY SETTING)
1500 345 487 554 569 654 745 784 835 896
060
COOLIN G
(FIELD SETTING)
1800 567 663 794 917 948 1015 1048 1155 1175
060
HEATING (3 TUBE)
(FACTORY SETTING)
1500 345 487 554 569 654 745 784 835 896
060
HEATING (4 TUBE)
(FACTORY SETTING)
1700 504 603 698 771 831 1043 1102 1155 1202
060
HEATING (5 TUBE)
(FACTORY SETTING)
1700 504 603 698 771 831 1043 1102 1155 1202
1.
Above data includes allowances for a dry coil, gas heat exchanger and no filters. For additional pressure drops, refer to Tables 11
and 12.