TABLE 11: HEATING CAPACITIES - 3 TON (BHP036)
CFM
RETURN
AIR °F
CAP
1
& KW
OUTDOOR AIR TEMPERATURE, °F (72% RH)
-10 0 10 20 30 40 50 60
900
55
MBH 10.597 12.792 15.448 18.660 22.545 27.244 32.929 39.804
KW 1.791 1.898 2.005 2.112 2.219 2.326 2.433 2.540
70
MBH 9.420 11.615 14.271 17.483 21.368 26.067 31.752 38.627
KW 2.198 2.305 2.412 2.519 2.626 2.733 2.840 2.947
80
MBH 7.543 9.738 12.394 15.606 19.491 24.190 29.875 36.750
KW 2.476 2.583 2.690 2.797 2.904 3.011 3.118 3.225
1200
55
MBH 11.652 13.847 16.503 19.715 23.600 28.299 33.984 40.859
KW 1.825 1.932 2.039 2.146 2.253 2.360 2.467 2.574
70
MBH 10.475 12.670 15.326 18.538 22.423 27.122 32.807 39.682
KW 2.232 2.339 2.446 2.553 2.660 2.767 2.874 2.981
80
MBH 8.598 10.793 13.449 16.661 20.546 25.245 30.930 37.805
KW 2.510 2.617 2.724 2.831 2.938 3.045 3.152 3.259
1500
55
MBH 12.282 14.477 17.133 20.345 24.230 28.929 34.614 41.489
KW 1.779 1.886 1.993 2.100 2.207 2.314 2.421 2.528
70
MBH 11.105 13.300 15.956 19.168 23.053 27.752 33.437 40.312
KW 2.186 2.293 2.400 2.507 2.614 2.721 2.828 2.935
80
MBH 9.228 11.423 14.079 17.291 21.176 25.875 31.560 38.435
KW 2.464 2.571 2.678 2.785 2.892 2.999 3.106 3.213
1.
These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have
been added.
TABLE 12: HEATING CAPACITIES - 3-1/2 TON (BHP042)
CFM
RETURN
AIR °F
CAP
1
& KW
OUTDOOR AIR TEMPERATURE, °F (72% RH)
-10 0 10 20 30 40 50 60
1050
55
MBH 15.404 17.988 20.968 24.404 28.369 32.941 38.215 44.298
KW 2.410 2.505 2.599 2.694 2.789 2.883 2.978 3.073
70
MBH 14.342 16.926 19.906 23.342 27.307 31.879 37.153 43.236
KW 2.835 2.930 3.024 3.119 3.214 3.308 3.403 3.498
80
MBH 13.669 16.253 19.233 22.669 26.634 31.206 36.480 42.563
KW 3.143 3.238 3.332 3.427 3.522 3.616 3.711 3.806
1400
55
MBH 17.901 20.485 23.465 26.901 30.866 35.438 40.712 46.795
KW 2.419 2.514 2.608 2.703 2.798 2.892 2.987 3.082
70
MBH 16.839 19.423 22.403 25.839 29.804 34.376 39.650 45.733
KW 2.844 2.939 3.033 3.128 3.223 3.317 3.412 3.507
80
MBH 16.166 18.750 21.730 25.166 29.131 33.703 38.977 45.060
KW 3.152 3.247 3.341 3.436 3.531 3.625 3.720 3.815
1750
55
MBH 18.901 21.485 24.465 27.901 31.866 36.438 41.712 47.795
KW 2.463 2.558 2.652 2.747 2.842 2.936 3.031 3.126
70
MBH 17.839 20.423 23.403 26.839 30.804 35.376 40.650 46.733
KW 2.888 2.983 3.077 3.172 3.267 3.361 3.456 3.551
80
MBH 17.166 19.750 22.730 26.166 30.131 34.703 39.977 46.060
KW 3.196 3.291 3.385 3.480 3.575 3.669 3.764 3.859
1.
These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have
been added.